Endress+Hauser
Endress+Hauser Differential pressure Deltabar PMD55
REQUEST A QUOTE
Accuracy | 0,1% "PLATINUM" 0,075% |
---|---|
Max. measurement error | 0,1% "PLATINUM" 0,075% |
Process temperature | -40 °C...85 °C (-40 °F...185 °F) |
Medium temperature range | Temperature gradient from pressure piping |
Pressure measuring range | 10mbar...40bar (0.15...580psi) |
Process pressure / max. overpressure limit | 160 bar |
Main wetted parts | 316L |
Max. process pressure | 10 mbar...40 bar (0.15...580 psi) |
Material process membrane | 316L, AlloyC, |
Measuring cell | 10 mbar...40 bar (0.15...580 psi) |
Measuring principle | Differential pressure |
Product headline | Digital transmitter with metallic measuring diaphragms Compact size Modular transmitter Long-term stability |
Max. measurement error | 0,1% "PLATINUM" 0,075% |
Max. process pressure | 10mbar...40bar (0.15...580psi) |
Medium temperature range | Temperature gradient from pressure piping |
Display/Operation | Option |
Outputs | 4...20mA HART |
Digital communication | HART |
Hazardous area approvals | ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS |
Functional safety | SIL |
Material certificates | NACE MR0103 NACE MR0175 EN10204-3.1 |
Measuring principle | Differential pressure |
Characteristic | Digital transmitter with metallic measuring diaphragms Compact size Modular transmitter Long-term stability |
Supply voltage | 4...20 mA HART 11,5...45V DC (Non Ex): Ex ia: 11,5...30V DC PROFIBUS PA: 9...32 V DC (Non Ex) FOUNDATION Fieldbus: 9...32 V DC (Non Ex) |
Reference Accuracy | Standard 0.1% Platinum 0.075% |
Long term stability | 0.05% of URL/ year 0.13% of URL/ 5 years 0.23% of URL/ 10 years |
Process temperature | -40°C...+85°C (-40°F...+185°F) |
Ambient temperature | -40°C...+85°C (-40°F...+185°F) |
Measuring cell | 10 mbar...40 bar (0.15...580 psi) |
Smallest calibratable span | 10 mbar (0.15 psi) |
Max. Turn down | 20:1 |
Max. overpressure limit | on one side: 160 bar (2300 psi) |
Process connection | 1/4-18 NPT |
Material process membrane | 316L, AlloyC, |
Material gasket | Viton, PTFE, EPDM, NBR |
Fill fluid | Silicone oil Inert oil |
Material housing | Die-cast aluminum |
Communication | 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus |
Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex |
Safety approvals | SIL |
Design approvals | NACE MR0175 EN10204-3.1 |
Successor | PMD55B |
Measuring principle | Differential pressure |
Product headline | Digital transmitter with metallic measuring diaphragms Compact size Modular transmitter Long-term stability |
Max. measurement error | 0,1% "PLATINUM" 0,075% |
Max. process pressure | 10mbar...40bar (0.15...580psi) |
Medium temperature range | Temperature gradient from pressure piping |
Display/Operation | Option |
Outputs | 4...20mA HART |
Digital communication | HART |
Hazardous area approvals | ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS |
Functional safety | SIL |
Material certificates | NACE MR0103 NACE MR0175 EN10204-3.1 |
Measuring principle | Differential pressure |
Characteristic / Application | Digital transmitter with metallic measuring diaphragms Compact size Modular transmitter Long-term stability |
Supply / Communication | 4...20mA HART: 11,5...45V DC Ex ia: 11,5...30V DC |
Accuracy | 0,1% "PLATINUM" 0,075% |
Long term stability | 0,05% of URL/year 0,125% of URL/5 years |
Ambient temperature | -40°C...85°C (-40°F...185°F) |
Process temperature | -40 °C...85 °C (-40 °F...185 °F) |
Process pressure / max. overpressure limit | 160 bar |
Pressure measuring range | 10mbar...40bar (0.15...580psi) |
Main wetted parts | 316L |
Process connection | 1/4-18 NPT |
Communication | 4...20mA HART PROFIBUS PA FOUNDATION Fieldbus |
Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI |
Safety approvals | SIL |
Design approvals | EN 10204-3.1 NACE MR0175, MR0103 AD2000 |
Options | 4-line digital display Aluminium housing |
Successor | PMD55B |
Application limits | Measuring cell: Metal welded |
Measuring principle | Differential pressure |
Product headline | Digital transmitter with metallic measuring diaphragms Compact size Modular transmitter Long-term stability |
Max. measurement error | 0,1% "PLATINUM" 0,075% |
Max. process pressure | 10 mbar...40 bar (0.15...580 psi) |
Medium temperature range | Temperature gradient from pressure piping |
Display/Operation | Option |
Outputs | 4...20mA HART |
Digital communication | HART |
Hazardous area approvals | ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS |
Functional safety | SIL |
Material certificates | NACE MR0103 NACE MR0175 EN10204-3.1 |
Returns Policy