Endress+Hauser Differential pressure Deltabar FMD78

Write a Review

REQUEST A QUOTE

Endress+Hauser Differential pressure Deltabar FMD78
Accuracy0,075% + influence of diaphragm seal
Process temperature-40°C...400°C
(-40°F...752°F)
Pressure measuring range100mbar...40bar
(1.5psi ... 600 psi)
Process pressure / max. overpressure limit160bar (2400 psi)
Main wetted partsAlloy C276
316L
Monel
Tantalum
Max. measurement distance400m (1312ft) H2O
Material process membrane316L, AlloyC,
Tantal,
Gold-Rhodium
PTFE
Measuring cell100 mbar...40 bar
(40 inH2O...600 psi)
Measuring principleDifferential pressure
CharacteristicDigital transmitter with metallic measuring diaphragms diaphragm seals and capillaries
Modular transmitter
Long-term stability
Secondary process barrier
enhanced safety via self diagnostic functions.



Supply voltage4...20 mA HART
10,5...45V DC (Non Ex):
Ex ia: 10,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)



Reference Accuracy0,075% + influence of diaphragm seal
Long term stability0.08 % of URL/ year
0.14 % of URL/ 5 years
0.27 % of URL/ 10 years
Process temperature-70°C...400°C
(-94°F...752°F)
Ambient temperature-50°C...85°C
(-58°F...185°F)
Measuring cell100 mbar...40 bar
(40 inH2O...600 psi)
Smallest calibratable span5 mbar (0.075 psi)
Vacuum resistance50 mbar (0.73 psi)
Max. Turn down100:1
Max. overpressure limit160 bar
(2400 psi)
Process connectionDiaphragm seal (Pancake, threads)
Flanges (DIN, ASME)
Hygienic connections
Tri-Clamp ISO2852
Process connection hygienicTri-Clamp
DIN11851
NEUMO
Varivent
SMS
DRD
Universal adapter
Material process membrane316L, AlloyC,
Tantal,
Gold-Rhodium
PTFE
Material gasketNone, diaphragm seal welded
Fill fluidSilicone oil,
Inert oil,
Vegetable oil
Low- temperature oil
High- temperature oil
Material housing316L, Die-cast aluminum
Communication4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / ApprovalsATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC, UK Ex
Safety approvalsSIL
Design approvalsNACE MR0175
EN10204-3.1
Hygienic approvals3A, FDA
Marine approvalsGL/ ABS
SpecialitiesDiagnostic functions
TempC Membrane
SuccessorPMD78B
Measuring principleDifferential pressure
Characteristic / ApplicationDigital transmitter with metallic measuring diaphragms diaphragm seals and capillaries
Modular transmitter
Long term stability
Enhanced safety via self diagnostic functions
Secondary process barrier
SpecialitiesTempC membrane
Supply / Communication4...20 mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUDATION Fieldbus:
9...32V DC
Accuracy0,075% + influence of diaphragm seal
Long term stability0,05% of URL/year
Ambient temperature-50°C...85°C
(-58°F...185°F)
Process temperature-40°C...400°C
(-40°F...752°F)
Process pressure / max. overpressure limit160bar (2400 psi)
Pressure measuring range100mbar...40bar
(1.5psi ... 600 psi)
Main wetted partsAlloy C276
316L
Monel
Tantalum
Process connectionDiaphragm seal (Pancakes, threads)
Flanges (DIN, ASME)
Tri-Clamp ISO2852
Hygienic connections
Process connection hygienicTri-Clamp
DIN11851
NEUMO
Varivent
SMS
DRD
Universal adapter
Max. measurement distance400m (1312ft) H2O
Communication4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / ApprovalsATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC
Safety approvalsSIL
Design approvalsEN10204-3.1
NACE MR0175, MR0103
Hygienic approvals3A, EHEDG
Marine approvalGL/ ABS
OptionsHistoROM/M-Dat
4-line digital display
SS- or Aluminiumhousing
Separate housing
SuccessorPMD78B
Application limitsMeasuring cell:
Metal welded