Endress+Hauser
Endress+Hauser Cerabar PMP71B - pressure transmitter
REQUEST A QUOTE
Accuracy | Standard: up to 0.05 % Platinum: up to 0.025 % |
---|---|
Process temperature | Standard: -40°C…+125°C (-40°F…+257°F) Diaphragm seal: -40°C...+400°C (-40°F...+752°F) |
Pressure measuring range | 400 mbar...700 bar (1.5 psi...10,500 psi) |
Main wetted parts | 316L, AlloyC, Tantal, Monel, PTFE, Gold |
Material process membrane | 316L, AlloyC, Tantal, Monel, PTFE, Gold |
Measuring cell | 400 mbar...700 bar (6 psi...10,500 psi) |
Measuring principle | Absolute and gauge pressure |
Characteristic | Pressure transmitter with metallic process diaphragm. Available with diaphragm seals. Device health verification without process interruptions. Intuitive and clear wizards for commissioning, proof tests and verification. |
Supply voltage | 4...20 mA HART Ex d, Ex e, non-Ex: 10.5...35V DC : Ex i: 10.5...30V DC |
Reference Accuracy | Standard: up to 0.05 % Platinum: up to 0.025 % |
Long term stability | 0.05 % of URL/ year 0.07 % of URL/ 5 years 0.10 % of URL/ 10 years |
Process temperature | Standard: -40°C…+125°C (-40°F…+257°F) Diaphragm seal: -70°C...+400°C (-94°F...+752°F) |
Ambient temperature | -60°C...+80°C (-76°F...+185°F) |
Measuring cell | 400 mbar...700 bar (6 psi...10,500 psi) |
Smallest calibratable span | 5 mbar (0.075 psi) |
Vacuum resistance | 5 mbar (0.725 psi) |
Max. Turn down | 100:1 |
Max. overpressure limit | 2,800 bar (40,600 psi) |
Process connection | Thread: G1/2...G2, R1/2, MNPT3/4...MNPT2, FNPT1/2, R1/2 Flange: DN25...DN100, NPS 1"...4" Pancake: 2"...4", DN50...DN100 |
Material process membrane | 316L, AlloyC, Tantal, Monel, PTFE, Gold |
Material gasket | PTFE |
Fill fluid | Silicone oil, Inert oil, Vegetable oil, High/ low temperature oil |
Material housing | Aluminium, 316L |
Communication | 4...20 mA HART PROFINET with Ethernet-APL Bluetooth® wireless technology and app (optional) |
Certificates / Approvals | ATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex |
Safety approvals | SIL |
Design approvals | EN10204-3.1, NACE MR0103, NACE MR0175 |
Marine approvals | Marine approvals |
Drinking water approvals | NSF |
Specialities | Heartbeat Technology, Bluetooth® Operation and maintenance SmartBlue App, LED Module, RFID TAG for easy identification, Plug and play functionalities, HistoROM |
Measuring principle | Absolute and gauge pressure |
Characteristic / Application | Pressure transmitter with metallic process diaphragm. Available with diaphragm seals. Device health verification without process interruptions. Intuitive and clear wizards for commissioning, proof tests and verification. |
Specialities | Heartbeat Technology, Bluetooth® Operation and maintenance SmartBlue App, LED Module, RFID TAG for easy identification, Plug and play functionalities, HistoROM |
Supply / Communication | Ex d, Ex e, non-Ex: 10.5...35V DC Ex i: 10.5...30V DC |
Accuracy | Standard: up to 0.05 % Platinum: up to 0.025 % |
Long term stability | 0.05 % of URL/ year 0.07 % of URL/ 5 years 0.10 % of URL/ 10 years |
Ambient temperature | -60°C...+80°C (-76°F...+185°F) |
Process temperature | Standard: -40°C…+125°C (-40°F…+257°F) Diaphragm seal: -40°C...+400°C (-40°F...+752°F) |
Process pressure / max. overpressure limit | 700 bar (10,500 psi) |
Pressure measuring range | 400 mbar...700 bar (1.5 psi...10,500 psi) |
Main wetted parts | 316L, AlloyC, Tantal, Monel, PTFE, Gold |
Process connection | Thread: G1/2...G2, R1/2, MNPT3/4...MNPT2, FNPT1/2, R1/2 Flange: DN25...DN100, NPS 1"...4" Pancake: 2"...4", DN50...DN100 |
Max. measurement distance | 7000 m (22,966 ft) H2O |
Communication | 4...20 mA HART PROFINET with Ethernet-APL Bluetooth® wireless technology and app (optional) |
Certificates / Approvals | ATEX, IEC Ex, CSA C/US, NEPSI |
Safety approvals | SIL |
Design approvals | EN 10204-3.1 NACE MR0175, NACE MR0103 |
Marine approval | Marine approval |
Drinking water approvals | NSF |
Metrological approvals and certificates | MID |
Options | Touch control display Diaphragm seal |
Application limits | Measuring cell: Metal welded If pressurized, possibly use differential pressure measurement with two pressure transmitters (electronic dp). Observe ratio head pressure: hydrostatic pressure |
Returns Policy