Endress+Hauser Cerabar PMC71B - pressure transmitter

Write a Review

REQUEST A QUOTE

Endress+Hauser Cerabar PMC71B - pressure transmitter
AccuracyStandard:
up to 0.05 %
Platinum:
up to 0.025 %
Process temperature-40°C...+150°C
(-40°F...+302°F)
Pressure measuring range100 mbar...40 bar
(1.5 psi...600 psi)
Main wetted partsCeraphire ceramic
FKM, EPDM, HNBR,
Perlast, Kalrez, Chemraz
Material process membraneCeramic
Measuring cell100 mbar....40 bar
(1.5 psi...600 psi)
Measuring principleAbsolute and gauge pressure
CharacteristicPremium accuracy pressure transmitter with dry ceramic cell.
Intuitive and clear wizards for commissioning, proof tests and verification.
Supply voltageEx d, Ex e, non-Ex:
10.5...35V DC
Ex i: 10.5...30V DC

Reference AccuracyStandard:
up to 0.05 %
Platinum:
up to 0.025 %

Long term stability0.05 % of URL/ year
0.08 % of URL/ 5 years
0.10 % of URL/ 10 years
Process temperature-40°C...+150°C
(-40°F...+302°F)
Ambient temperature-40°C...+85°C
(-40°C...+185°F)
Measuring cell100 mbar....40 bar
(1.5 psi...600 psi)
Smallest calibratable span5 mbar (0.075 psi)
Vacuum resistance0 mbar abs.
Max. Turn down100:1
Max. overpressure limit60 bar (900 psi)
Process connectionThread:
G1/2...G2, R1/2, MNPT1/2...MNPT2, FNPT1/2
Flange:
DN25...DN80,
NPS 1"...4"
Material process membraneCeramic
Material gasketFKM, EPDM, HNBR, FFKM
Fill fluidnone, dry measuring cell
Material housingAluminium, 316L
Communication4...20 mA HART
PROFINET with Ethernet-APL
Bluetooth® wireless
technology and app (optional)
Certificates / ApprovalsATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex
Safety approvalsSIL
Design approvalsEN10204-3.1
Drinking water approvalsNSF, KTW
SpecialitiesHeartbeat Technology,
Bluetooth® Operation and maintenance SmartBlue App,
LED Module,
RFID TAG for easy identification,
Plug and play functionalities,
HistoROM
Measuring principleAbsolute and gauge pressure
Characteristic / ApplicationPremium accuracy pressure transmitter with dry ceramic cell.
Intuitive and clear wizards for commissioning, proof tests and verification.
SpecialitiesHeartbeat Technology,
Bluetooth® Operation and maintenance SmartBlue App,
LED Module,
RFID TAG for easy identification,
Plug and play functionalities,
HistoROM
Supply / CommunicationEx d, Ex e, non-Ex::
10.5...35V DC
Ex i: 10.5...30V DC
AccuracyStandard:
up to 0.05 %
Platinum:
up to 0.025 %
Long term stability0.05 % of URL/ year
0.08 % of URL/ 5 years
0.10 % of URL/ 10 years
Ambient temperature-40°C...+85°C
(-40°F...+185°F)
Process temperature-40°C...+150°C
(-40°F...+302°F)
Process pressure / max. overpressure limit60 bar (900 psi)
Pressure measuring range100 mbar...40 bar
(1.5 psi...600 psi)
Main wetted partsCeraphire ceramic
FKM, EPDM, HNBR,
Perlast, Kalrez, Chemraz
Process connectionThread:
G1/2...G2, R1/2, MNPT1/2...MNPT2, FNPT1/2
Flange:
DN25...DN80,
NPS 1"...4"
Max. measurement distance400 m (1312 ft) H2O
Communication4...20 mA HART
PROFINET with Ethernet-APL
Bluetooth® wireless
technology and app (optional)
Certificates / ApprovalsATEX, IEC Ex, CSA C/US, NEPSI
Safety approvalsSIL
Design approvalsEN 10204-3.1
Drinking water approvalsNSF, KTW
Metrological approvals and certificatesMID
OptionsTouch control display
Application limitsMeasuring cell: ceramics
If pressurized, possibly
use differential pressure
measurement with two
pressure transmitters
(electronic dp). Observe
ratio head pressure :
hydrostatic pressure
Returns Policy

Related Products

Top