Endress+Hauser
Endress+Hauser Cerabar PMC51B - pressure transmitter
REQUEST A QUOTE
Accuracy | Standard: up to 0.075 % Platinum: up to 0.055 % |
---|---|
Process temperature | -40°C...+100°C (-40°F...+212°F) |
Pressure measuring range | 100 mbar...40 bar (1.5 psi...600 psi) |
Main wetted parts | Ceraphire ceramic FKM, EPDM, HNBR, Perlast, Kalrez |
Material process membrane | Ceramic |
Measuring cell | 100 mbar...40 bar (1.5 psi...600 psi) |
Measuring principle | Absolute and gauge pressure |
Characteristic | Pressure transmitter with ceramic process membran for accurate measurement in liquid or gases. Intuitive and clear wizard for commissioning |
Supply voltage | Ex d, Ex e, non-Ex: 10.5...35V DC Ex i: 10.5...30V DC |
Reference Accuracy | Standard: up to 0.075 % Platinum: up to 0.055 % |
Long term stability | 0.10% of URL/ year 0.25% of URL/ 5 years 0.40% of URL/ 10 years |
Process temperature | -40°C...+100°C (-40°F...+212°F) |
Ambient temperature | -40°C...+85°C (-40°F...+185°F) |
Measuring cell | 100 mbar...40 bar (1.5 psi...600 psi) |
Smallest calibratable span | 5 mbar (0.075 psi) |
Vacuum resistance | 0 mbar abs. |
Max. Turn down | 100:1 |
Max. overpressure limit | 60 bar (900 psi) |
Process connection | Thread: G1/2...G2, R1/2, MNPT1/2...MNPT2, FNPT1/2 Flange: DN25...DN80, NPS 1"...4" |
Material process membrane | Ceramic |
Material gasket | FKM, EPDM, HNBR, FFKM |
Fill fluid | none, dry measuring cell |
Material housing | Aluminium |
Communication | 4...20 mA, 4...20 mA HART PROFINET with Ethernet-APL Bluetooth® wireless technology and app (optional) |
Certificates / Approvals | ATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex |
Safety approvals | SIL |
Design approvals | EN10204-3.1 NACE MR0175, NACE MR0103 |
Drinking water approvals | NSF, KTW |
Specialities | Bluetooth® Operation and maintenance SmartBlue App, RFID TAG for easy identification, Plug and play functionalities |
Measuring principle | Absolute and gauge pressure |
Characteristic / Application | Pressure transmitter with ceramic process membran for accurate measurement in liquid or gases. Intuitive and clear wizard for commissioning |
Specialities | Bluetooth® Operation and maintenance SmartBlue App, RFID TAG for easy identification, Plug and play functionalities |
Supply / Communication | Ex d, Ex e, non-Ex:: 10.5...35V DC Ex i: 10.5...30V DC |
Accuracy | Standard: up to 0.075 % Platinum: up to 0.055 % |
Long term stability | 0.10 % of URL/ year 0.25 % of URL/ 5 years 0.40 % of URL/ 10 years |
Ambient temperature | -40°C...+85°C (-40°F...+185°F) |
Process temperature | -40°C...+100°C (-40°F...+212°F) |
Process pressure / max. overpressure limit | 40 bar (600 psi) |
Pressure measuring range | 100 mbar...40 bar (1.5 psi...600 psi) |
Main wetted parts | Ceraphire ceramic FKM, EPDM, HNBR, Perlast, Kalrez |
Process connection | Thread: G1/2...G2, R1/2, MNPT1/2...MNPT2, FNPT1/2 Flange: DN25...DN80, NPS 1"...4" |
Max. measurement distance | 400 m (1312 ft) H2O |
Communication | 4...20 mA, 4...20 mA HART PROFINET with Ethernet-APL Bluetooth® wireless technology and app (optional) |
Certificates / Approvals | ATEX, IEC Ex, CSA C/US, NEPSI |
Safety approvals | SIL |
Design approvals | EN 10204-3.1 NACE MR0175, NACE MR0103 |
Drinking water approvals | NSF, KTW |
Application limits | Measuring cell: ceramics If pressurized, possibly use differential pressure measurement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure |