Endress+Hauser Cerabar PMC51B - pressure transmitter

Write a Review

REQUEST A QUOTE

Endress+Hauser Cerabar PMC51B - pressure transmitter
AccuracyStandard:
up to 0.075 %
Platinum:
up to 0.055 %
Process temperature-40°C...+100°C
(-40°F...+212°F)
Pressure measuring range100 mbar...40 bar
(1.5 psi...600 psi)
Main wetted partsCeraphire ceramic
FKM, EPDM, HNBR,
Perlast, Kalrez
Material process membraneCeramic
Measuring cell100 mbar...40 bar
(1.5 psi...600 psi)
Measuring principleAbsolute and gauge pressure
CharacteristicPressure transmitter with ceramic process membran for accurate measurement in liquid or gases.
Intuitive and clear wizard for commissioning
Supply voltageEx d, Ex e, non-Ex:
10.5...35V DC
Ex i: 10.5...30V DC

Reference AccuracyStandard:
up to 0.075 %
Platinum:
up to 0.055 %


Long term stability0.10% of URL/ year
0.25% of URL/ 5 years
0.40% of URL/ 10 years
Process temperature-40°C...+100°C
(-40°F...+212°F)
Ambient temperature-40°C...+85°C
(-40°F...+185°F)
Measuring cell100 mbar...40 bar
(1.5 psi...600 psi)
Smallest calibratable span5 mbar (0.075 psi)
Vacuum resistance0 mbar abs.
Max. Turn down100:1
Max. overpressure limit60 bar (900 psi)
Process connectionThread:
G1/2...G2, R1/2, MNPT1/2...MNPT2,
FNPT1/2
Flange:
DN25...DN80,
NPS 1"...4"
Material process membraneCeramic
Material gasketFKM, EPDM, HNBR, FFKM
Fill fluidnone, dry measuring cell
Material housingAluminium
Communication4...20 mA,
4...20 mA HART
PROFINET with Ethernet-APL
Bluetooth® wireless
technology and app (optional)
Certificates / ApprovalsATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex
Safety approvalsSIL
Design approvalsEN10204-3.1
NACE MR0175,
NACE MR0103
Drinking water approvalsNSF, KTW
SpecialitiesBluetooth® Operation and maintenance SmartBlue App,
RFID TAG for easy identification,
Plug and play functionalities
Measuring principleAbsolute and gauge pressure
Characteristic / ApplicationPressure transmitter with ceramic process membran for accurate measurement in liquid or gases.
Intuitive and clear wizard for commissioning
SpecialitiesBluetooth® Operation and maintenance SmartBlue App,
RFID TAG for easy identification,
Plug and play functionalities
Supply / CommunicationEx d, Ex e, non-Ex::
10.5...35V DC
Ex i: 10.5...30V DC
AccuracyStandard:
up to 0.075 %
Platinum:
up to 0.055 %
Long term stability0.10 % of URL/ year
0.25 % of URL/ 5 years
0.40 % of URL/ 10 years
Ambient temperature-40°C...+85°C
(-40°F...+185°F)
Process temperature-40°C...+100°C
(-40°F...+212°F)
Process pressure / max. overpressure limit40 bar (600 psi)
Pressure measuring range100 mbar...40 bar
(1.5 psi...600 psi)
Main wetted partsCeraphire ceramic
FKM, EPDM, HNBR,
Perlast, Kalrez
Process connectionThread:
G1/2...G2, R1/2, MNPT1/2...MNPT2, FNPT1/2
Flange:
DN25...DN80,
NPS 1"...4"
Max. measurement distance400 m (1312 ft) H2O
Communication4...20 mA,
4...20 mA HART
PROFINET with Ethernet-APL
Bluetooth® wireless
technology and app (optional)
Certificates / ApprovalsATEX, IEC Ex, CSA C/US, NEPSI
Safety approvalsSIL
Design approvalsEN 10204-3.1
NACE MR0175,
NACE MR0103
Drinking water approvalsNSF, KTW
Application limitsMeasuring cell: ceramics
If pressurized, possibly use differential pressure measurement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure
Returns Policy