Endress+Hauser Capacitance Point level detection Solicap FTI77

Write a Review

REQUEST A QUOTE

Endress+Hauser Capacitance Point level detection Solicap FTI77
Process temperature-50°C ... 400°C
(-58°F ... 752°F)
Process pressure / max. overpressure limitVacuum ... 10 bar
(Vacuum ... 145 psi)
Measuring principleCapacitive Solid
Characteristic / ApplicationPartly isolated sword probe / rope probe for very high temperatures
High mech. lateral load
SpecialitiesInactive length
Active build-up compensation
High lateral loading
Extremely robust probe
Supply / Communication19 ... 253V AC
10 ... 55V DC-PNP
19...253V AC bzw 10...55V DC
8/16mA, 11 ... 36V DC
PFM
3-wire
Ambient temperature-50°C ... 70°C
(-58°F ... 158°F)
Process temperature-50°C ... 400°C
(-58°F ... 752°F)
Process pressure / max. overpressure limitVacuum ... 10 bar
(Vacuum ... 145 psi)
Main wetted partsCeramic, 316L, Steel
Max. tensile strengthRope: 20 kN
Process connectionThread R1 1/2, NPT1 1/2
Flanges DN/ASME/JIS
Sensor lengthRope: 0.5 ... 20m
(1.6 ... 65ft)
Sword: 0.2m ... 1m
(0.6 ... 3.3ft)
Inactive length: 0.1m ... 1m
(0.3 ... 3.3ft)
Communication2- wire 19-253 VAC
DC PNP
Relais DPDT
PFM
3-wire
8/16 mA
Certificates / ApprovalsATEX, FM, CSA, IEC Ex, EAC
Safety approvalsSIL
Design approvalsEN 10204-3.1
ComponentsPFM: FTC325, FTC625, FTC470Z, FTC471Z
3-wire: FTC325
Application limitsDK min. 2.5
Returns Policy

Related Products