Process temperature | -80 °C ... +200 °C (-112 °F ... +392 °F) |
---|---|
Process pressure / max. overpressure limit | Vacuum ... 100 bar (Vacuum ... 1450 psi) |
Measuring principle | Capacitive Liquid |
Characteristic / Application | Capacitive rod probe |
Specialities | Interface detection Foam detection |
Ambient temperature | -50 °C ... +70 °C (-58 °F ... +158 °F) With separate housing: -50 °C ... +120 °C (-58 °F ... +248°F) |
Process temperature | -80 °C ... +200 °C (-112 °F ... +392 °F) |
Process pressure / max. overpressure limit | Vacuum ... 100 bar (Vacuum ... 1450 psi) |
Main wetted parts | Insulation material: PTFE, PFA 316L |
Process connection | G 1/2 ... 1 1/2 NPT 1/2 ... 1 1/2 Flange from DN25.../ASME 1".../JIS 10K... |
Process connection hygienic | Tri-Clamp ISO2852 gap free plated Dairy coupling Flush mount |
Sensor length | Total length of probe: max 6 m (20 ft) |
Communication | 2- wire 19-253 VAC 3-wire PFM Relay DPDT DC-PNP 8/16 mA |
Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI, EAC |
Safety approvals | Overfill prevention WHG SIL |
Design approvals | EN 10204-3.1 NACE MR0175 |
Marine approval | GL/ ABS/ DNV |
Options | Inactive length Fully isolated active build-up compensation Ground tube Separate housing |
Components | Transmitter PFM: FTC325, FTC625, FTC470Z, FTC471Z 3-wire: FTC325 |
Application limits | Notice the pressure and temperature derating. Notice for non conductive medium the DK. |