Endress+Hauser Capacitance Level measurement Liquicap FMI52

Write a Review

REQUEST A QUOTE

Endress+Hauser Capacitance Level measurement Liquicap FMI52
Accuracyrepeatablity 0,1%
Process temperature-80°C...200°C
-112°F...392°F
Process pressure / max. overpressure limitVacuum ... 100 bar
(Vaccum ... 1450 psi)
Max. measurement distance0.42 m ... 10.0 m
(1.38 ft ... 33 ft)
Main wetted partsInsulation material: FEP,PFA
316L
Measuring principleCapacitive
Characteristic / ApplicationFully insulated rope probe, for standard and extreme process conditions (temperature, pressure)
Interface measurementInterfaces liquid / liquid also with emulsion layers
SpecialitiesInactive length
Factory calibrated
short response time by change of value

Supply / Communication12-36V DC HART
PFM
Accuracyrepeatablity 0,1%
Linearity error for conductive liquids<0,25%
Ambient temperature-50°C...+70°C
-58°F...+158°F
Process temperature-80°C...200°C
-112°F...392°F
Process pressure / max. overpressure limitVacuum ... 100 bar
(Vaccum ... 1450 psi)
Main wetted partsInsulation material: FEP,PFA
316L
Process connectionG 3/4, G 1, G1 1/2 /NPT 3/4", NPT 1, NPT1 1/2"
Flange from DN25.../ASME 1".../JIS...
Process connection hygienicTri-Clamp ISO02852 gap free plated
Dairy coupling
Flush-mounted seal
Sensor lengthTotal length: 6m (20ft)
Inactive length: max. 2m (7ft)
Max. measurement distance0.42 m ... 10.0 m
(1.38 ft ... 33 ft)
Communication4...20mA HART
PFM
Certificates / ApprovalsATEX, FM, CSA, IEC Ex, TIIS, INMETRO, NEPSI, EAC
Safety approvalsSIL
Design approvalsEN 10204-3.1
NACE MR0175
Hygienic approvalsEHEDG
Marine approvalGL/ ABS/ DNV
OptionsSeparate housing
gas-tight probe seal
Application limitsChanging, non-conductive
media, conductivity
< 100 μS/cm
Notice the pressure and temperature derating
Returns Policy

Related Products

Top