Endress+Hauser
Endress+Hauser Capacitance Level measurement Liquicap FMI52
REQUEST A QUOTE
Accuracy | repeatablity 0,1% |
---|---|
Process temperature | -80°C...200°C -112°F...392°F |
Process pressure / max. overpressure limit | Vacuum ... 100 bar (Vaccum ... 1450 psi) |
Max. measurement distance | 0.42 m ... 10.0 m (1.38 ft ... 33 ft) |
Main wetted parts | Insulation material: FEP,PFA 316L |
Measuring principle | Capacitive |
Characteristic / Application | Fully insulated rope probe, for standard and extreme process conditions (temperature, pressure) |
Interface measurement | Interfaces liquid / liquid also with emulsion layers |
Specialities | Inactive length Factory calibrated short response time by change of value |
Supply / Communication | 12-36V DC HART PFM |
Accuracy | repeatablity 0,1% |
Linearity error for conductive liquids | <0,25% |
Ambient temperature | -50°C...+70°C -58°F...+158°F |
Process temperature | -80°C...200°C -112°F...392°F |
Process pressure / max. overpressure limit | Vacuum ... 100 bar (Vaccum ... 1450 psi) |
Main wetted parts | Insulation material: FEP,PFA 316L |
Process connection | G 3/4, G 1, G1 1/2 /NPT 3/4", NPT 1, NPT1 1/2" Flange from DN25.../ASME 1".../JIS... |
Process connection hygienic | Tri-Clamp ISO02852 gap free plated Dairy coupling Flush-mounted seal |
Sensor length | Total length: 6m (20ft) Inactive length: max. 2m (7ft) |
Max. measurement distance | 0.42 m ... 10.0 m (1.38 ft ... 33 ft) |
Communication | 4...20mA HART PFM |
Certificates / Approvals | ATEX, FM, CSA, IEC Ex, TIIS, INMETRO, NEPSI, EAC |
Safety approvals | SIL |
Design approvals | EN 10204-3.1 NACE MR0175 |
Hygienic approvals | EHEDG |
Marine approval | GL/ ABS/ DNV |
Options | Separate housing gas-tight probe seal |
Application limits | Changing, non-conductive media, conductivity < 100 μS/cm Notice the pressure and temperature derating |