Endress+Hauser Capacitance Level measurement Liquicap FMI51

Write a Review

REQUEST A QUOTE

Endress+Hauser Capacitance Level measurement Liquicap FMI51
AccuracyRepeatablity 0,1%
Process temperature-80°C...200°C
-112°F...392°F
Process pressure / max. overpressure limitVacuum ... 100 bar
(Vaccum ... 1450 psi)
Max. measurement distance0.1 m ... 4.0 m
(0.3 ft ... 13 ft)
Main wetted partsInsulation material: PTFE,PFA
316L
Measuring principleCapacitive
Characteristic / ApplicationFully insulated rod probe, for standart- and extreme process conditions (temperature, pressure, build-up)
Interface measurementInterfaces liquid / liquid also with emulsion layers
SpecialitiesInactive length
Factory calibrated
short response time by change of value

Supply / Communication12-36V DC HART
PFM
AccuracyRepeatablity 0,1%
Linearity error for conductive liquids<0,25%
Ambient temperature-50°C...+70°C
-58°F...+158°F
Process temperature-80°C...200°C
-112°F...392°F
Process pressure / max. overpressure limitVacuum ... 100 bar
(Vaccum ... 1450 psi)
Main wetted partsInsulation material: PTFE,PFA
316L
Process connectionG1/2, G 3/4, G 1, G1 1/2 /NPT 1/2, NPT 3/4, NPT 1", NPT1 1/2
Flanges from DN25.../ASME 1".../JIS...
Process connection hygienicTri-Clamp ISO02852 gap free plated
Dairy coupling
Flush-mounted seal
Sensor lengthTotal length: 6m (20ft)
Inactive length: max. 2m (7ft)
Max. measurement distance0.1 m ... 4.0 m
(0.3 ft ... 13 ft)
Communication4...20mA HART
PFM
Certificates / ApprovalsATEX, FM, CSA, IEC Ex, TIIS, INMETRO, NEPSI, EAC
Safety approvalsSIL
Design approvalsEN 10204-3.1
NACE MR0175
Hygienic approvals3A, EHEDG
Marine approvalGL/ ABS/ DNV
OptionsSeparate housing
gas-tight probe seal
Application limitsInsufficient clearance towards ceiling
Changing, non-conductive
media, conductivity
< 100 μS/cm
Notice the pressure and temperature derating
Returns Policy