Endress+Hauser
Endress+Hauser Capacitance Level measurement Liquicap FMI21
REQUEST A QUOTE
Accuracy | < 1% |
---|---|
Process temperature | -40 °C ... 100 °C (-40 °F ... 212 °F) |
Process pressure / max. overpressure limit | Vacuum ... 10 bar (Vacuum ... 145 psi) |
Max. measurement distance | 2.5 m (8 ft) |
Main wetted parts | Probe rods: 316L/1.4404 / PP Option: carbon fibre PP coated |
Measuring principle | Capacitive |
Characteristic / Application | Two-rod probe Preconfigured from factory 0%...100% High quality, non-corrosive materials (carbon fibre, stainless steel) Suitable for aggressive liquids (many acids and alkalis) |
Specialities | Probe shorting kit available |
Supply / Communication | 10 ... 30VDC |
Accuracy | < 1% |
Ambient temperature | -40 °C ... 70 °C (-40 °F ... 158 °F) |
Process temperature | -40 °C ... 100 °C (-40 °F ... 212 °F) |
Process pressure / max. overpressure limit | Vacuum ... 10 bar (Vacuum ... 145 psi) |
Main wetted parts | Probe rods: 316L/1.4404 / PP Option: carbon fibre PP coated |
Process connection | G 1½ NPT 1½ |
Sensor length | Total length of probe 2.5 m |
Max. measurement distance | 2.5 m (8 ft) |
Communication | 4 ... 20 mA |
Certificates / Approvals | ATEX, CSA, CSA C/US |
Safety approvals | Overfill prevention WHG |
Options | Display |
Application limits | Changing, non-conductive media, conductivity < 3 0 μS/cm Highly viscous liquids > 2 000 cst |
Returns Policy