Endress+Hauser Capacitance Level measurement Liquicap FMI21

Write a Review

REQUEST A QUOTE

Endress+Hauser Capacitance Level measurement Liquicap FMI21
Accuracy< 1%
Process temperature-40 °C ... 100 °C
(-40 °F ... 212 °F)
Process pressure / max. overpressure limitVacuum ... 10 bar
(Vacuum ... 145 psi)
Max. measurement distance2.5 m (8 ft)
Main wetted partsProbe rods:
316L/1.4404 / PP
Option: carbon fibre PP coated
Measuring principleCapacitive
Characteristic / ApplicationTwo-rod probe
Preconfigured from factory 0%...100%
High quality, non-corrosive materials (carbon fibre, stainless steel)
Suitable for aggressive liquids (many acids and alkalis)


SpecialitiesProbe shorting kit available
Supply / Communication10 ... 30VDC
Accuracy< 1%
Ambient temperature-40 °C ... 70 °C
(-40 °F ... 158 °F)
Process temperature-40 °C ... 100 °C
(-40 °F ... 212 °F)
Process pressure / max. overpressure limitVacuum ... 10 bar
(Vacuum ... 145 psi)
Main wetted partsProbe rods:
316L/1.4404 / PP
Option: carbon fibre PP coated
Process connectionG 1½
NPT 1½
Sensor lengthTotal length of probe 2.5 m
Max. measurement distance2.5 m (8 ft)
Communication4 ... 20 mA
Certificates / ApprovalsATEX, CSA, CSA C/US
Safety approvalsOverfill prevention WHG
OptionsDisplay
Application limitsChanging, non-conductive
media, conductivity
< 3 0 μS/cm
Highly viscous liquids
> 2 000 cst
Returns Policy

Related Products

Top