Endress+Hauser
Endress+Hauser Automatic water sampler Liquistation CSF28
REQUEST A QUOTE
Functions | Stationary sampler |
---|---|
Suction height | 6 m (19.69 ft) suction height 8 m (26.25 ft) suction height |
Cabinet | Plastic ASA+PC |
Process temperature | Sample temperature: 2 to 50 °C (36 to 122 °F) |
Process pressure | Max. 0.8 bar (Max. 11.6 psi) |
Measuring principle | Sampler |
Functions | Stationary sampler |
Application | Municipal and industrial wastewater treatment plants: - Self-monitoring - Process monitoring - Monitoring of dischargers Monitoring of wastewater systems, authorities and water management offices: - Water pollution control and water quality - Monitoring of dischargers |
Dosing system | Vacuum pump system Peristaltic pump system |
Suction height | 6 m (19.69 ft) suction height 8 m (26.25 ft) suction height |
Cabinet | Plastic ASA+PC |
Distribution | Possible |
Process temperature | Sample temperature: 2 to 50 °C (36 to 122 °F) |
Cooling | Active, dynamic cooling unit |
Process pressure | Max. 0.8 bar (Max. 11.6 psi) |
Heating | Evaporator and defrosting unit mounted in compact housing |
Input | Analogue: 1, galvanically isolated Binary: 1, galvanically isolated |
Output / communication | Alarm relay |
Interface | CDI Optional: Webserver |
Data logger | All events and data Sampling statistics |
Power supply | 100 to 120/200 to 240 V AC ±10 %, 50/60 Hz |
Dimension | 1.258 x 753 x 625 mm (h x w x d) 49.5 x 29.7 x 24.6 inch (h x w x d) |
Weight | 101 kg |
Accessories | Housing equipment Bottle configurations Hoses |
Options | Webserver |
Returns Policy