Endress+Hauser Absolute and gauge pressure Cerabar PMP51

Write a Review

REQUEST A QUOTE

Endress+Hauser Absolute and gauge pressure Cerabar PMP51
AccuracyStandard 0.1%
Platinum 0.075%
Process temperature-40°C...130°C
(-40°F...266°F)
Pressure measuring range1 bar...400 bar
(15 psi...6000 psi)
Process pressure / max. overpressure limit600 bar (9000 psi)
Main wetted parts316L
Max. measurement distance4000 m (13.123 ft) H2O
Material process membrane316L, AlloyC,
Rhodium>Gold
Measuring cell400mbar...400bar
(15psi...6000psi)
relative/ absolute
Measuring principleAbsolute and gauge pressure
CharacteristicSmart and reliable pressure transmitter, with piezoresistive measuring cell
and metal welded process isolating
diaphragm

Supply voltage4...20mA HART
11,5...45V DC (Non Ex):
Ex ia: 11,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)



Reference AccuracyStandard 0.1%
Platinum 0.075%
Long term stability0.1% of URL/year
0.2% of URL/ 5 years
0.25% of URL/ 10 years
Process temperature-40°C...+130°C
(-40°F...+266°F
+150°C for 1h
(+302°F for 1h)
Ambient temperature-40°C...+85°C
(-40°F...+185°F)
Measuring cell400mbar...400bar
(15psi...6000psi)
relative/ absolute
Smallest calibratable span20 mbar (0.3 psi)
Vacuum resistance10 mbar (0.15 psi)
Max. Turn down20:1
Max. overpressure limit600bar (9000psi)
Process connectionThread:
G1/2...G2, MNPT1/2...MNPT2
Flange:
DN25...DN80,
ASME 1 1/2"...4",
Process connection hygienicTri-Clamp
DIN11851
NEUMO
Varivent N
SMS
DRD
Material process membrane316L, AlloyC,
Rhodium>Gold
Material gasketNone, measuring cell welded
Fill fluidSilicone oil,
Inert oil
Material housingDie-cast aluminum,
AISI 316L
Communication4...20 mA
4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
IO-Link
Certificates / ApprovalsATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex
Safety approvalsSIL
Design approvalsEN10204-3.1
NACE MR0175
Hygienic approvals3A, EHEDG
CoC ASME-BPE
Marine approvalsGL/ ABS/ LR/ BV/ DNV
Drinking water approvalsNSF
SuccessorPMP51B
Measuring principleAbsolute and gauge pressure
Characteristic / ApplicationSmart and reliable pressure transmitter, with piezoresistive measuring cell
and metal welded process isolating
diaphragm
Supply / Communication4 ..20 mA HART:
11,5...45 V DC
Ex ia: 11,5...30 V DC
PROFIBUS PA
FOUNDATION Fieldbus
AccuracyStandard 0.1%
Platinum 0.075%
Long term stability< 0,1% von URL/ year
0,2% of URL/ 5 years
0,25% of URL/ 10 years
Ambient temperature-40°C...85°C
(-40°F...185°F)
Process temperature-40°C...130°C
(-40°F...266°F)
Process pressure / max. overpressure limit600 bar (9000 psi)
Pressure measuring range1 bar...400 bar
(15 psi...6000 psi)
Main wetted parts316L
Process connectionThreads
Flanges (DIN, ASME, JIS)
Hygienic connections
Tri-Clamp ISO2852
Max. measurement distance4000 m (13.123 ft) H2O
Communication4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
IO-Link
Certificates / ApprovalsATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI
Safety approvalsSIL
Design approvalsEN 10204-3.1
NACE MR0175, MR0103
AD2000
Hygienic approvals3A, EHEDG
CoC ASME-BPE
Marine approvalGL/ ABS/ LR/ BV/ DNV
Drinking water approvalsNSF
OptionsLocal display
SuccessorPMP51B
Application limitsMeasuring cell: Metal welded
If pressurized, possibly use differential pressure meas-urement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure