Accuracy | Standard 0.1% Platinum 0.075% |
---|---|
Process temperature | -40°C...130°C (-40°F...266°F) |
Pressure measuring range | 1 bar...400 bar (15 psi...6000 psi) |
Process pressure / max. overpressure limit | 600 bar (9000 psi) |
Main wetted parts | 316L |
Max. measurement distance | 4000 m (13.123 ft) H2O |
Material process membrane | 316L, AlloyC, Rhodium>Gold |
Measuring cell | 400mbar...400bar (15psi...6000psi) relative/ absolute |
Measuring principle | Absolute and gauge pressure |
Characteristic | Smart and reliable pressure transmitter, with piezoresistive measuring cell and metal welded process isolating diaphragm |
Supply voltage | 4...20mA HART 11,5...45V DC (Non Ex): Ex ia: 11,5...30V DC PROFIBUS PA: 9...32 V DC (Non Ex) FOUNDATION Fieldbus: 9...32 V DC (Non Ex) |
Reference Accuracy | Standard 0.1% Platinum 0.075% |
Long term stability | 0.1% of URL/year 0.2% of URL/ 5 years 0.25% of URL/ 10 years |
Process temperature | -40°C...+130°C (-40°F...+266°F +150°C for 1h (+302°F for 1h) |
Ambient temperature | -40°C...+85°C (-40°F...+185°F) |
Measuring cell | 400mbar...400bar (15psi...6000psi) relative/ absolute |
Smallest calibratable span | 20 mbar (0.3 psi) |
Vacuum resistance | 10 mbar (0.15 psi) |
Max. Turn down | 20:1 |
Max. overpressure limit | 600bar (9000psi) |
Process connection | Thread: G1/2...G2, MNPT1/2...MNPT2 Flange: DN25...DN80, ASME 1 1/2"...4", |
Process connection hygienic | Tri-Clamp DIN11851 NEUMO Varivent N SMS DRD |
Material process membrane | 316L, AlloyC, Rhodium>Gold |
Material gasket | None, measuring cell welded |
Fill fluid | Silicone oil, Inert oil |
Material housing | Die-cast aluminum, AISI 316L |
Communication | 4...20 mA 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus IO-Link |
Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex |
Safety approvals | SIL |
Design approvals | EN10204-3.1 NACE MR0175 |
Hygienic approvals | 3A, EHEDG CoC ASME-BPE |
Marine approvals | GL/ ABS/ LR/ BV/ DNV |
Drinking water approvals | NSF |
Successor | PMP51B |
Measuring principle | Absolute and gauge pressure |
Characteristic / Application | Smart and reliable pressure transmitter, with piezoresistive measuring cell and metal welded process isolating diaphragm |
Supply / Communication | 4 ..20 mA HART: 11,5...45 V DC Ex ia: 11,5...30 V DC PROFIBUS PA FOUNDATION Fieldbus |
Accuracy | Standard 0.1% Platinum 0.075% |
Long term stability | < 0,1% von URL/ year 0,2% of URL/ 5 years 0,25% of URL/ 10 years |
Ambient temperature | -40°C...85°C (-40°F...185°F) |
Process temperature | -40°C...130°C (-40°F...266°F) |
Process pressure / max. overpressure limit | 600 bar (9000 psi) |
Pressure measuring range | 1 bar...400 bar (15 psi...6000 psi) |
Main wetted parts | 316L |
Process connection | Threads Flanges (DIN, ASME, JIS) Hygienic connections Tri-Clamp ISO2852 |
Max. measurement distance | 4000 m (13.123 ft) H2O |
Communication | 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus IO-Link |
Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI |
Safety approvals | SIL |
Design approvals | EN 10204-3.1 NACE MR0175, MR0103 AD2000 |
Hygienic approvals | 3A, EHEDG CoC ASME-BPE |
Marine approval | GL/ ABS/ LR/ BV/ DNV |
Drinking water approvals | NSF |
Options | Local display |
Successor | PMP51B |
Application limits | Measuring cell: Metal welded If pressurized, possibly use differential pressure meas-urement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure |