Endress+Hauser
Endress+Hauser Absolute and gauge pressure Cerabar PMC71
REQUEST A QUOTE
Accuracy | Standard: 0.05% Platinum: up to 0.025% |
---|---|
Process temperature | -40°C...150°C (-40°F...302°F) |
Pressure measuring range | 100mbar...40bar (1.5psi...600psi) |
Process pressure / max. overpressure limit | 60bar (900psi) |
Main wetted parts | Ceraphire ceramic Alloy C 316L Monel PVDF |
Max. measurement distance | 400m (1312ft) H2O |
Material process membrane | Ceramic |
Measuring cell | 100 mbar...40 bar (1.5 psi...600 psi) relative/ absolute |
Measuring principle | Absolute and gauge pressure |
Characteristic | Digital transmitter with capacitive sensor and ceramic membrane Modular transmitter Long term stability Enhanced safety via self diagnostic functions Secondary process barrier |
Supply voltage | 4...20 mA HART 10,5...45V DC (Non Ex): Ex ia: 10,5...30V DC PROFIBUS PA: 9...32 V DC (Non Ex) FOUNDATION Fieldbus: 9...32 V DC (Non Ex) |
Reference Accuracy | Standard: 0.05% Platinum: up to 0.025% |
Long term stability | 0.05 % of URL/ year 0.08 % of URL/ 5 years 0.1 % of URL/ 10 years |
Process temperature | -20°C...150°C (-4°F...257°F) |
Ambient temperature | -40°C...85°C (-40°F...185°F) |
Measuring cell | 100 mbar...40 bar (1.5 psi...600 psi) relative/ absolute |
Smallest calibratable span | 5 mbar (0.075 psi) |
Vacuum resistance | 0 mbar abs. |
Max. Turn down | 100:1 |
Max. overpressure limit | 60 bar (900 psi) |
Process connection | Thread: G1/2...G2, R1/2, MNPT1/2...MNPT2 Flange: DN25...DN80, ASME 1"...4", JIS 10K |
Process connection hygienic | Tri-Clamp DIN11851 Varivent N SMS DRD |
Material process membrane | Ceramic |
Material gasket | Viton, EPDM, Chemraz, Kalrez, NBR |
Fill fluid | none, dry measuring cell |
Material housing | Die-cast aluminum, AISI 316L |
Communication | 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus |
Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC, UK Ex |
Design approvals | EN10204-3.1 |
Hygienic approvals | 3A, EHEDG |
Marine approvals | GL/ ABS |
Drinking water approvals | NSF |
Specialities | Diagnostic functions |
Successor | PMC71B |
Measuring principle | Absolute and gauge pressure |
Characteristic / Application | Digital transmitter with capacitive sensor and ceramic membrane Modular transmitter Long term stability Enhanced safety via self diagnostic functions Secondary process barrier |
Specialities | diagnostic functionalities different languages in software |
Supply / Communication | 4...20mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC |
Accuracy | Standard: 0.05% Platinum: up to 0.025% |
Long term stability | 0,05% of URL/year |
Ambient temperature | -40°C...85°C (-40°F...185°F) |
Process temperature | -40°C...150°C (-40°F...302°F) |
Process pressure / max. overpressure limit | 60bar (900psi) |
Pressure measuring range | 100mbar...40bar (1.5psi...600psi) |
Main wetted parts | Ceraphire ceramic Alloy C 316L Monel PVDF |
Process connection | Threads Flanges Tri-Clamp ISO2852 Hygienic connections |
Max. measurement distance | 400m (1312ft) H2O |
Communication | 4 ... 20 mA HART PROFIBUS PA FOUNDATION Fieldbus |
Certificates / Approvals | ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC |
Design approvals | EN 10204-3.1 |
Marine approval | GL/ ABS |
Drinking water approvals | NSF |
Options | HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing |
Successor | PMC71B |
Application limits | Measuring cell: ceramics If pressurized, possibly use differential pressure measurement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure |