Endress+Hauser
Endress+Hauser Absolute and gauge pressure Cerabar PMC51
REQUEST A QUOTE
Accuracy | Standard 0.1% Platinum 0.075% |
---|---|
Process temperature | -20°C...130°C (-4°F...266°F) |
Pressure measuring range | 100 mbar...40 bar (1.5psi...600psi) |
Process pressure / max. overpressure limit | 60 bar (900 psi) |
Main wetted parts | Ceraphire Sealing Alloy C276 316L |
Max. measurement distance | 400 m (1312 ft) H2O |
Material process membrane | Ceramic |
Measuring cell | 100 mbar...40 bar (1.5 psi...600 psi) relative/ absolute |
Measuring principle | Absolute and gauge pressure |
Characteristic | Smart and reliable pressure transmitter with capacitive measuring cell and ceramic process isolating diaphragm Ceraphire) |
Supply voltage | 4...20 mA HART 11,5...45V DC (Non Ex): Ex ia: 11,5...30V DC PROFIBUS PA: 9...32 V DC (Non Ex) FOUNDATION Fieldbus: 9...32 V DC (Non Ex) |
Reference Accuracy | Standard 0.1% Platinum 0.075% |
Long term stability | 0.2% of URL/ year 0.4% of URL/ 5 years 0.5% of URL/ 10 years |
Process temperature | -40°C...+130°C (-40°F...+266°F +150°C for 1h (+302°F for 1h) |
Ambient temperature | -40°C...+85°C (-40°F...+185°F) |
Measuring cell | 100 mbar...40 bar (1.5 psi...600 psi) relative/ absolute |
Smallest calibratable span | 10 mbar (0.15 psi) |
Vacuum resistance | 0 mbar abs. |
Max. Turn down | 20:1 |
Max. overpressure limit | 60 bar (900 psi) |
Process connection | Thread: G1/2...G2, R1/2, MNPT1/2 Flange: DN25...DN80, ASME 1"...4", JIS 10K |
Process connection hygienic | Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent N SMS DRD |
Material process membrane | Ceramic |
Material gasket | Viton, EPDM, NBR, Kalrez |
Fill fluid | None, dry measuring cell |
Material housing | Die-cast aluminum, AISI 316L |
Communication | 4...20 mA 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus IO-Link |
Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex |
Safety approvals | SIL |
Design approvals | EN10204-3.1 NACE MR0175 |
Hygienic approvals | CoC ASME-BPE 3A, EHEDG |
Marine approvals | GL/ ABS/ LR/ BV/ DNV |
Drinking water approvals | NSF |
Successor | PMC51B |
Measuring principle | Absolute and gauge pressure |
Characteristic / Application | Smart and reliable pressure transmitter, with capacitive measuring cell and ceramic process isolating diaphragm (Ceraphire) |
Supply / Communication | 4 ..20 mA HART: 11,5...45V DC Ex ia: 11,5...30V DC PROFIBUS PA FOUNDATION Fieldbus |
Accuracy | Standard 0.1% Platinum 0.075% |
Long term stability | < 0,1% of URL/ year < 0,25% of URL/ 5 years < 0,4% of URL/ 10 years |
Ambient temperature | -40°C...85°C (-40°F...185°F) |
Process temperature | -20°C...130°C (-4°F...266°F) |
Process pressure / max. overpressure limit | 60 bar (900 psi) |
Pressure measuring range | 100 mbar...40 bar (1.5psi...600psi) |
Main wetted parts | Ceraphire Sealing Alloy C276 316L |
Process connection | Threads Flanges (DIN, ASME, JIS) |
Max. measurement distance | 400 m (1312 ft) H2O |
Communication | 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus IO-Link |
Certificates / Approvals | ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI |
Safety approvals | SIL |
Design approvals | EN 10204-3.1 NACE MR0175, MR0103 |
Hygienic approvals | 3A, EHEDG CoC ASME-BPE |
Marine approval | GL/ ABS/ LR/ BV/ DNV |
Drinking water approvals | NSF |
Options | Local display |
Successor | PMC51B |
Application limits | Measuring cell: ceramics If pressurized, possibly use differential pressure measurement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure |
Returns Policy