Endress+Hauser
Endress+Hauser 9W4B Proline Prosonic Flow W 400 ultrasonic flowmeter
REQUEST A QUOTE
Max. measurement error | Volume flow: ±3% o.r. for DN15 ±2% o.r. for DN25 to 200 ±2% o.r. above DN200 |
---|---|
Measuring range | 0 to 15 m/s (0 to 50 ft/s) |
Medium temperature range | –40 to +130 °C (–40 to +266 °F) |
Max. process pressure | N/A |
Measuring principle | Ultrasonic flow |
Product headline | Clamp-on meter with Heartbeat Technology and web server for the water and wastewater industry. Short inlet run thanks to FlowDC. Bidirectional measurement for water and wastewater as well as process water and hydropower plants. |
Sensor features | Low capital investment – cost-effectiveness increases with pipe diameter (up to DN 4000/156"). Long-term stable signal – maintenance-free permanent mounting from outside with coupling pads. Reliable measurement on various pipe materials – sensor for GRP and plastic pipes available. Mounting without process interruption. Wide nominal diameter range: DN 15 to 4000 (½ to 160"). Medium temperature up to +130 °C (+266 °F). |
Transmitter features | Safe operation – no need to open the device due to display with touch control, background lighting. Full remote access – web server. Integrated diagnostics, verification and monitoring – Heartbeat Technology. Transmitter housing made of durable polycarbonate or aluminium. Remote version for wall mounting. Integrated data logger: measured values monitoring. |
Nominal diameter range | DN15 to 4000 (1/2 to 160") |
Sensor materials | Clamp on system: Sensor holder 1.4301 (304), 1.4404 (316L) Sensor housing 1.4301 (304), 1.4404 (316L) Strapping bands 1.4301 (304), 1.4404 (316L) |
Measured variables | Volume flow, Flow velocity, Sound velocity |
Max. measurement error | Volume flow: ±3% o.r. for DN15 ±2% o.r. for DN25 to 200 ±2% o.r. above DN200 |
Measuring range | 0 to 15 m/s (0 to 50 ft/s) |
Max. process pressure | N/A |
Medium temperature range | –40 to +130 °C (–40 to +266 °F) |
Ambient temperature range | Sensor DN 15 to 65: -40 to 130°C Sensor DN 50 to 4000: -40 to 130°C |
Sensor housing material | N/A |
Transmitter housing material | Wall-mounted housing Polycarbonat; AlSi10Mg, coated |
Degree of protection | Transmitter: IP66/67, Type 4X enclosure Sensor: IP66/67, Type 4X enclosure, IP68, Type 6P enclosure (optional) |
Display/Operation | 4‐line backlit display with touch control (operation from outside) Configuration via local display, web browser and operating tools possible |
Outputs | 3 ouputs: 4‐20 mA/4‐20 mA HART (active) Pulse/frequency/switch output (passive) Pulse/frequency/switch output (passive) |
Inputs | Status input |
Digital communication | HART |
Power supply | AC 100 to 240 V / AC/DC 24 V |
Approvals | cCSAus |
Other approvals and certificates | Other approvals and certificates |
Product safety | CE, C-tick marking, EAC-marking |
Metrological approvals and certificates | Flowmeter verification for all frequencies except 0.3 MHz, reference line size: 5 MHz DN 50, all other frequencies DN 100 Verification performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a |
Marine approvals and certificates | Marine approvals and certificates |
Returns Policy