Max. measurement errorVolume flow:
±3% o.r. for DN15
±2% o.r. for DN25 to 200
±2% o.r. above DN200
Measuring range0 to 15 m/s (0 to 50 ft/s)
Medium temperature range–40 to +130 °C (–40 to +266 °F)
Max. process pressureN/A
Measuring principleUltrasonic flow
Product headlineClamp-on meter with Heartbeat Technology and web server for the water and wastewater industry.
Short inlet run thanks to FlowDC.
Bidirectional measurement for water and wastewater as well as process water and hydropower plants.
Sensor featuresLow capital investment – cost-effectiveness increases with pipe diameter (up to DN 4000/156"). Long-term stable signal – maintenance-free permanent mounting from outside with coupling pads. Reliable measurement on various pipe materials – sensor for GRP and plastic pipes available.
Mounting without process interruption. Wide nominal diameter range: DN 15 to 4000 (½ to 160"). Medium temperature up to +130 °C (+266 °F).
Transmitter featuresSafe operation – no need to open the device due to display with touch control, background lighting. Full remote access – web server. Integrated diagnostics, verification and monitoring – Heartbeat Technology.
Transmitter housing made of durable polycarbonate or aluminium. Remote version for wall mounting. Integrated data logger: measured values monitoring.
Nominal diameter rangeDN15 to 4000 (1/2 to 160")
Sensor materialsClamp on system:
Sensor holder 1.4301 (304), 1.4404 (316L)
Sensor housing 1.4301 (304), 1.4404 (316L)
Strapping bands 1.4301 (304), 1.4404 (316L)
Measured variablesVolume flow, Flow velocity, Sound velocity
Max. measurement errorVolume flow:
±3% o.r. for DN15
±2% o.r. for DN25 to 200
±2% o.r. above DN200
Measuring range0 to 15 m/s (0 to 50 ft/s)
Max. process pressureN/A
Medium temperature range–40 to +130 °C (–40 to +266 °F)
Ambient temperature rangeSensor DN 15 to 65: -40 to 130°C
Sensor DN 50 to 4000: -40 to 130°C
Sensor housing materialN/A
Transmitter housing materialWall-mounted housing
Polycarbonat; AlSi10Mg, coated
Degree of protectionTransmitter: IP66/67, Type 4X enclosure
Sensor: IP66/67, Type 4X enclosure, IP68, Type 6P enclosure (optional)
Display/Operation4‐line backlit display with touch control (operation from outside)
Configuration via local display, web browser and operating tools possible
Outputs3 ouputs:
4‐20 mA/4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Pulse/frequency/switch output (passive)
InputsStatus input
Digital communicationHART
Power supplyAC 100 to 240 V / AC/DC 24 V
ApprovalscCSAus
Other approvals and certificatesOther approvals and certificates
Product safetyCE, C-tick marking, EAC-marking
Metrological approvals and certificatesFlowmeter verification for all frequencies except 0.3 MHz, reference line size: 5 MHz DN 50, all other frequencies DN 100
Verification performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a
Marine approvals and certificatesMarine approvals and certificates