Max. measurement error | Volume flow: ±3% o.r. for DN 15 ±2% o.r. for DN 25 to DN 200 ±2% o.r. above DN 200 |
---|---|
Measuring range | 0 to 15 m/s (0 to 50 ft/s) |
Medium temperature range | DN 15 to 65 (½to 2½"): –40 to +150°C (–40 +302 °F) DN 50 to 4000 (2 to 160"): –40 to +170°C (–40 to +338 °F) |
Max. process pressure | N/A |
Measuring principle | Ultrasonic flow |
Product headline | Clamp-on flowmeter for limited spaces in process industries with up to 3 I/Os. Constant accuracy even when mounted with short inlet run thanks to FlowDC. Bidirectional measurement of various fluids, e.g. liquid hydrocarbons and chemicals. |
Sensor features | High safety standards – SIL by design, international hazardous area approvals. Long-term stable signal – maintenance-free permanent mounting from outside with coupling pads. Reliable measurement on various pipe materials – sensor for GRP and plastic pipes available. Mounting without process interruption. Wide nominal diameter range: DN 15 to 4000 (½ to 160"). Medium temperature: –40 to +170 °C (–40 to +338 °F). |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 3 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal diameter range | Dual channel, 1 or 2 paths : DN 15 to 4000 (1/2 to 160") |
Sensor materials | Clamp on system: Sensor holder 1.4301/304, 1.4404/316L Sensor housing 1.4301/304, 1.4404/316L Strapping bands 1.4301/304, 1.4404/316L |
Measured variables | Volume flow, sound velocity, flow velocity, totalizer |
Max. measurement error | Volume flow: ±3% o.r. for DN 15 ±2% o.r. for DN 25 to DN 200 ±2% o.r. above DN 200 |
Measuring range | 0 to 15 m/s (0 to 50 ft/s) |
Max. process pressure | N/A |
Medium temperature range | DN 15 to 65 (½to 2½"): –40 to +150°C (–40 +302 °F) DN 50 to 4000 (2 to 160"): –40 to +170°C (–40 to +338 °F) |
Ambient temperature range | –40 to +60 °C (–40 to +140 °F) –50 to +60 °C (–58 to +140 °F) optional |
Sensor housing material | N/A |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L |
Degree of protection | Sensor remote version: IP68 type 6P Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation | 4-line backlit display with touch control(operation from outside) Optional: WLAN Configuration via local display and operating tools possible |
Outputs | 3 outputs: 4-20 mA HART (active/passive) 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
Inputs | Status input 4-20 mA input |
Digital communication | HART, Modbus RS485 |
Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, FM/CSA, EAC, UK Ex |
Other approvals and certificates | Other approvals and certificates |
Product safety | CE, C-tick, EAC-marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Flowmeter verification for all frequencies except 0.3 MHz, reference line size: 5 MHz DN 50, all other frequencies DN 100 Verification performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a |