Endress+Hauser
Endress+Hauser 9E1B Proline Prosonic Flow E 100 ultrasonic flowmeter
REQUEST A QUOTE
Max. measurement error | Volume flow: - ± 0.5 % o.r. ± 0.02% o.f.s. for 0.5 to 10 m/s (1.6 to 33 ft/s) - ± 0.07 % o.f.s. for flow velocities < 0.5 m/s (1.64 ft/s) |
---|---|
Measuring range | 0.025 to 5 m/s (0.02 to 16.4 ft/s) 0 to 6360 dm3/min (0 to 1680 gal/min) |
Medium temperature range | 0 to 150° (17.8 to 302 °F) |
Max. process pressure | PN 25 / ASME Cl. 150 |
Wetted materials | Measuring tube: 1.4301 (F304) Process Connection: 1.4571; 1.4404 (F316L); 1.0038 (S235JR); 1,4306 (F304L); 1.4307 (F304L); A105 |
Measuring principle | Ultrasonic flow |
Product headline | Economical Ultrasonic flowmeter with integrated temperature measurement. Bidirectional measuring of demineralized water applications for Utilities, e.g. boiler condensate return lines. |
Sensor features | Long-term stability – reliable, robust sensor. Reducing further measuring point – multivariable device. Dependable flow measurement – high turndown (200:1). Measurement accuracy up to ±0.5 % (flow) or according to EN 1434 Cl. 2, ±2.0 °C (± 3.6 °F) (temperature). Process temperatures up to 150 °C (302 °F). Entire meter housing made of stainless steel. |
Transmitter features | Time-saving local operation without additional software and hardware – integrated web server. Extended calibration intervals – integrated device verification due to Heartbeat Technology. Easy commissioning – brief parameter explanations. 4-20 mA HART, pulse/frequency output. Local display for reading and monitoring available. Robust transmitter housing. |
Nominal diameter range | DN 50 to 150 (2"to 6") |
Wetted materials | Measuring tube: 1.4301 (F304) Process Connection: 1.4571; 1.4404 (F316L); 1.0038 (S235JR); 1,4306 (F304L); 1.4307 (F304L); A105 |
Measured variables | Volume flow, calculated mass flow, flow velocity, sound velocity, temperature |
Max. measurement error | Volume flow: - ± 0.5 % o.r. ± 0.02% o.f.s. for 0.5 to 10 m/s (1.6 to 33 ft/s) - ± 0.07 % o.f.s. for flow velocities < 0.5 m/s (1.64 ft/s) |
Measuring range | 0.025 to 5 m/s (0.02 to 16.4 ft/s) 0 to 6360 dm3/min (0 to 1680 gal/min) |
Max. process pressure | PN 25 / ASME Cl. 150 |
Medium temperature range | 0 to 150° (17.8 to 302 °F) |
Ambient temperature range | -20 to 60 °C (-4 to 140 °F) |
Sensor housing material | Stainless steel |
Transmitter housing material | Compact: AlSi10Mg, coated Stainless steel, 1.4301 |
Degree of protection | Standard: IP66/67, Type 4X enclosure With opened housing: IP20, Type 1 enclosure |
Display/Operation | 4‐line backlit display available (no local operation) Configuration via web browser and operating tools possible |
Outputs | 4‐20 mA HART (active) Pulse/frequency/switch output (passive) |
Inputs | None |
Power supply | DC 19.2 to 28.8 V |
Hazardous area approvals | None |
Product safety | CE, C-Tick, EAC marking |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) Calibration according to EN 1434 Class 2 |
Pressure approvals and certificates | PED |
Material certificates | 3.1 material |
Returns Policy