Endress+Hauser 9E1B Proline Prosonic Flow E 100 ultrasonic flowmeter
Max. measurement errorVolume flow:
- ± 0.5 % o.r. ± 0.02% o.f.s. for 0.5 to 10 m/s (1.6 to 33 ft/s)
- ± 0.07 % o.f.s. for flow velocities < 0.5 m/s (1.64 ft/s)
Measuring range0.025 to 5 m/s (0.02 to 16.4 ft/s)
0 to 6360 dm3/min (0 to 1680 gal/min)
Medium temperature range0 to 150° (17.8 to 302 °F)
Max. process pressurePN 25 / ASME Cl. 150
Wetted materialsMeasuring tube: 1.4301 (F304)
Process Connection: 1.4571; 1.4404 (F316L); 1.0038 (S235JR); 1,4306 (F304L); 1.4307 (F304L); A105
Measuring principleUltrasonic flow
Product headlineEconomical Ultrasonic flowmeter with integrated temperature measurement.
Bidirectional measuring of demineralized water applications for Utilities, e.g. boiler condensate return lines.
Sensor featuresLong-term stability – reliable, robust sensor. Reducing further measuring point – multivariable device. Dependable flow measurement – high turndown (200:1).
Measurement accuracy up to ±0.5 % (flow) or according to EN 1434 Cl. 2, ±2.0 °C (± 3.6 °F) (temperature). Process temperatures up to 150 °C (302 °F). Entire meter housing made of stainless steel.
Transmitter featuresTime-saving local operation without additional software and hardware – integrated web server. Extended calibration intervals – integrated device verification due to Heartbeat Technology. Easy commissioning – brief parameter explanations.
4-20 mA HART, pulse/frequency output. Local display for reading and monitoring available. Robust transmitter housing.
Nominal diameter rangeDN 50 to 150 (2"to 6")
Wetted materialsMeasuring tube: 1.4301 (F304)
Process Connection: 1.4571; 1.4404 (F316L); 1.0038 (S235JR); 1,4306 (F304L); 1.4307 (F304L); A105
Measured variablesVolume flow, calculated mass flow, flow velocity, sound velocity, temperature
Max. measurement errorVolume flow:
- ± 0.5 % o.r. ± 0.02% o.f.s. for 0.5 to 10 m/s (1.6 to 33 ft/s)
- ± 0.07 % o.f.s. for flow velocities < 0.5 m/s (1.64 ft/s)
Measuring range0.025 to 5 m/s (0.02 to 16.4 ft/s)
0 to 6360 dm3/min (0 to 1680 gal/min)
Max. process pressurePN 25 / ASME Cl. 150
Medium temperature range0 to 150° (17.8 to 302 °F)
Ambient temperature range-20 to 60 °C (-4 to 140 °F)
Sensor housing materialStainless steel
Transmitter housing materialCompact:
AlSi10Mg, coated
Stainless steel, 1.4301
Degree of protectionStandard: IP66/67, Type 4X enclosure
With opened housing: IP20, Type 1 enclosure
Display/Operation4‐line backlit display available (no local operation)
Configuration via web browser and operating tools possible
Outputs4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
InputsNone
Power supplyDC 19.2 to 28.8 V
Hazardous area approvalsNone
Product safetyCE, C-Tick, EAC marking
Metrological approvals and certificatesCalibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Calibration according to EN 1434 Class 2
Pressure approvals and certificatesPED
Material certificates3.1 material
Returns Policy