Endress+Hauser 9B2B Proline Prosonic Flow B 200 ultrasonic flowmeter

Write a Review

REQUEST A QUOTE

Endress+Hauser 9B2B Proline Prosonic Flow B 200 ultrasonic flowmeter
Max. measurement errorVolume flow (standard):
‐ ±1.5 % o.r. for 3 to 30 m/s (9.84 to 98.4 ft/s)
‐ ±3 % o.r. for 1 to 3 m/s (3.28 to 9.84 ft/s)
Volume flow (option):
‐ ±0.1 % o.f.s. for 0.3 to 1 m/s (0.98 to 3.28 ft/s)
‐ ±1.5 % o.r. for 1 to 30 m/s (3.28 to 98.4 ft/s)
Measuring rangeStandard: 1 to 30 m/s (3.28 to 98.4 ft/s)
Option: 0.3 to 30 m/s (0.98 to 98.4 ft/s)
Medium temperature range0 to +80 °C (+32 to +176 °F)
Max. process pressure11 bar a (159 psi a)
Wetted materialsSensor: 1.4404/1.4435 (316L)
Transducer: HNBR
Temperature sensor (option): AFM 34
Measuring principleUltrasonic flow
Product headlineThe device for accurate, reliable biogas measurement with loop-powered technology.
Inline flowmeter designed for measurement of wet biogas and digester gas under fluctuating process conditions.
Sensor featuresOptimized for low pressure gas – specialized sensor design. No additional pressure loss – full-bore design. Process transparency – diagnostic capability.
Multivariable device: flow, temperature and methane. Medium temperature: 0 to 80 °C (32 to 176 °F). Process pressure: 0.7 to 11 bar a (10.2 to 159 psi a).
Transmitter featuresConvenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals.
Nominal diameter rangeSingle‐path version: DN 50 (2"), DN 80 (3")
Two‐path version: DN 100 to 200 (4 to 8")
Wetted materialsSensor: 1.4404/1.4435 (316L)
Transducer: HNBR
Temperature sensor (option): AFM 34

Measured variablesVolume flow, corrected volume flow, corrected methane volume flow, energy flow, methane fraction, calorific value, temperature
Max. measurement errorVolume flow (standard):
‐ ±1.5 % o.r. for 3 to 30 m/s (9.84 to 98.4 ft/s)
‐ ±3 % o.r. for 1 to 3 m/s (3.28 to 9.84 ft/s)
Volume flow (option):
‐ ±0.1 % o.f.s. for 0.3 to 1 m/s (0.98 to 3.28 ft/s)
‐ ±1.5 % o.r. for 1 to 30 m/s (3.28 to 98.4 ft/s)

Measuring rangeStandard: 1 to 30 m/s (3.28 to 98.4 ft/s)
Option: 0.3 to 30 m/s (0.98 to 98.4 ft/s)
Max. process pressure11 bar a (159 psi a)
Medium temperature range0 to +80 °C (+32 to +176 °F)
Ambient temperature rangeFlange material carbon steel: –10 to +60 °C (+14 to +140 °F)
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)
Transmitter housing materialAlSi10Mg, coated; 1.4404 (316L)
Degree of protectionIP66/67, type 4X enclosure
Display/Operation4‐line backlit display with touch control
(operation from outside)
Configuration via local display and operating tools possible
Outputs4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive)
InputsCurrent input 4‐20 mA (passive)
Digital communicationHART
Power supplyDC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch Output)
Hazardous area approvalsATEX, IECEx, cCSAus, NEPSI, INMETRO, JPN
Metrological approvals and certificatesCalibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Pressure approvals and certificatesPED
Material certificates3.1 material (wetted parts)