Endress+Hauser 8FE LPGmass Coriolis flowmeter

Write a Review

REQUEST A QUOTE

Endress+Hauser 8FE LPGmass Coriolis flowmeter
Max. measurement errorMass flow (liquid): ±0.2 %
Volume flow (liquid): ±0.3 %
Measuring range0 to 45 000 kg/h (0 to 1650 lb/min)
Medium temperature range–40 to +125 °C (–40 to +257 °F)
Max. process pressurePN 40, Class 300, 63K
Wetted materialsMeasuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Measuring principleCoriolis
Product headlineThe refueling and distribution application flowmeter with easy sytem
integration. Accurate measurement of liquefied petroleum gas in refueling
and distribution applications.

Sensor featuresExcellent operational safety – reliable under extreme ambient conditions.
Fewer process measuring points – multivariable measurement (flow,
density, temperature). Space‐saving installation – no in/outlet run needs.
Flow rates up to 45 000 kg/h (1654 lb/min). Volume flow calculation
according to API table 53.
Transmitter featuresEasy operation – reduced to application needs. Fast commissioning – pre‐configured devices. Automatic recovery of data for servicing. Robust, ultra‐compact transmitter housing. Pulse output and Modbus RS485.
Nominal diameter rangeDN 8 to 40 (³⁄₈ to 1½")
Wetted materialsMeasuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Measured variablesMass flow, density, temperature, volume flow, corrected volume flow
Max. measurement errorMass flow (liquid): ±0.2 %
Volume flow (liquid): ±0.3 %
Measuring range0 to 45 000 kg/h (0 to 1650 lb/min)
Max. process pressurePN 40, Class 300, 63K
Medium temperature range–40 to +125 °C (–40 to +257 °F)
Ambient temperature range–40 to +60 °C (–40 to +140 °F)
Sensor housing material1.4301 (304), corrosion resistant
Transmitter housing materialPowder‐coated die‐cast aluminium
Degree of protectionIP67, type 4X enclosure
Display/OperationNo local operation
Configuration via operating tools possible
OutputsPulse/frequency/switch output (passive), phase‐shifted pulse
InputsNone
Digital communicationModbus RS485
Power supplyDC 10 to 30 V
AC 20 to 28 V
Hazardous area approvalsATEX, IECEx, NEC/CEC, FM, CSA, NEPSI, UL
Other approvals and certificates3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), custody
transfer
PED, CRN
Metrological approvals and certificatesCalibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), custody transfer
Pressure approvals and certificatesPED, CRN
Material certificates3.1 material
Returns Policy