Max. measurement error | Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.5 % Density (liquid): ±0.0005 g/cm3 |
---|---|
Measuring range | 0 to 1000 kg/h (0 to 37 lb/min) |
Medium temperature range | –50 to +200 °C (–58 to +392 °F) |
Max. process pressure | PN 40, Class 300, 10K, 400 bar (5800 psi) |
Wetted materials | Measuring tube: 1.4539 (904L) Connection: 1.4539 (904L); 1.4404 (316/316L) |
Measuring principle | Coriolis |
Product headline | Compact sensor for smallest quantities with easy system integration. Measuring accurately smallest quantities of liquids and gases. |
Sensor features | Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor. Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 °C (+392 °F). |
Transmitter features | Cost savings – very low power consumption. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing. Robust transmitter housing. Modbus RS485. Pulse output. |
Nominal diameter range | DN 1 to 6 (¹⁄₂₄ to ¹⁄₄") |
Wetted materials | Measuring tube: 1.4539 (904L) Connection: 1.4539 (904L); 1.4404 (316/316L) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.5 % Density (liquid): ±0.0005 g/cm3 |
Measuring range | 0 to 1000 kg/h (0 to 37 lb/min) |
Max. process pressure | PN 40, Class 300, 10K, 400 bar (5800 psi) |
Medium temperature range | –50 to +200 °C (–58 to +392 °F) |
Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
Sensor housing material | 1.4301 (304), corrosion resistant |
Transmitter housing material | Powder‐coated die‐cast aluminium |
Degree of protection | IP67, type 4X enclosure |
Display/Operation | No local operation Configuration via operating tools possible |
Outputs | Pulse/frequency/switch output (passive), phase‐shifted pulse |
Inputs | None |
Digital communication | Modbus RS485 |
Power supply | DC 10 to 30 V AC 20 to 28 V |
Hazardous area approvals | ATEX, IECEx, NEC/CEC, NEPSI |
Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR CRN |
Metrological approvals and certificates | 3.1 material |
Pressure approvals and certificates | CRN |
Measuring principle | Coriolis |
Product headline | Compact sensor for smallest quantities with easy system integration. Measuring accurately smallest quantities of liquids and gases. |
Sensor features | Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor. Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 °C (+392 °F). |
Transmitter features | Cost savings – very low power consumption. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing. Robust transmitter housing. Modbus RS485. Pulse output. |
Nominal diameter range | DN 1 to 6 (¹⁄₂₄ to ¹⁄₄") |
Wetted materials | Measuring tube: 1.4539 (904L) Connection: 1.4539 (904L); 1.4404 (316/316L) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.5 % Density (liquid): ±0.0005 g/cm3 |
Measuring range | 0 to 1000 kg/h (0 to 37 lb/min) |
Max. process pressure | PN 40, Class 300, 10K, 400 bar (5800 psi) |
Medium temperature range | –50 to +200 °C (–58 to +392 °F) |
Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
Sensor housing material | 1.4301 (304), corrosion resistant |
Transmitter housing material | Powder‐coated die‐cast aluminium |
Degree of protection | IP67, type 4X enclosure |
Display/Operation | No local operation Configuration via operating tools possible |
Outputs | Pulse/frequency/switch output (passive), phase‐shifted pulse |
Inputs | None |
Digital communication | Modbus RS485 |
Power supply | DC 10 to 30 V AC 20 to 28 V |
Hazardous area approvals | ATEX, IECEx, NEC/CEC, NEPSI |
Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR CRN |