Endress+Hauser 71552786 Automatic cleaning system Liquiline Control CDC30 (230 VAC)

Write a Review

REQUEST A QUOTE

Endress+Hauser 71552786 Automatic cleaning system Liquiline Control CDC30 (230 VAC)
  • Technical Information (TI)

  • Stable measurements and easy maintenance for your pH/ORP measuring points with Liquiline Control. The product bundle consisting of the Liquiline CM448 transmitter, the Cleanfit Control CYC25 cleaning unit and the CYR10B cleaning injector ensures fully automatic cleaning of your sensors. All products are pre-assembled and wired on a mounting plate. The Chemoclean Plus software provides parameterizable flushing and/or cleaning programs. The system is compatible with Cleanfit retractable assemblie
    High process reliability and low maintenance

    Minimal downtime with Liquiline Control CDC30. With the system, you no longer have to worry about almost anything during measurements, as the system takes care of sensor cleaning completely. You save time and have less work, especially if the sensors in your application need to be cleaned frequently.

    Pre-configured and preassembled basic solution

    Simple and fast commissioning: Everything ready to go, all you have to do is quickly mount the panel on the wall and/or in the control cabinet. And since everything is already wired, the connection to your measuring point ist also done in no time at all.

    Adjustable, pre-configured cleaning programs

    Parameterizable rinsing and/or cleaning programs, either time-controlled or cycle-controlled – just as it suits your application.

    Rinsing and cleaning cycles without additional dosing pump

    The Chemoclean CYR10B cleaning injector for dosing cleaning concentrate is a spray cleaning system for pH/ORP sensors as well as for oxygen and turbidity sensors.

    Downloads
    Measuring principlePotentiometric
    ApplicationModular 4 wire controller
    Multichannel: 1 to 8 digital channels for Memosens protocol
    Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
    8 sensors connectable in any combination
    Functionality modular extendable at any time
    Plug and play for modules and sensors
    CharacteristicRobust plastic housing
    All non-ex applications
    Design8x Memosens input, 2 to 8x current output,
    Alarmrelay, 2x relay, SD card for software update and copy & paste of setup
    MaterialHousing base: PC-FR
    Housing seal EPDM
    Dimension237 x 194 x 162 mm
    9.33 x 7.64 x 6.38 inch
    Process temperature-20 to 55 °C (0 to 130 °F)
    Ingress protectionIP66 / IP67
    Input1 to 8x Memosens digital input
    2x 0/4 to 20mA Input optional
    2 to 4x Digital input optional
    Output / communication2 to 8x 0/4 to 20 mA current outputs, alarmrelay
    4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
    Additional certificationsEAC, cCSAus
    Measuring principleSensor ORP / Redox
    ApplicationModular 4 wire controller
    Multichannel: 1 to 8 digital channels for Memosens protocol
    Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
    8 sensors connectable in any combination
    Functionality modular extendable at any time
    Plug and play for modules and sensors
    CharacteristicRobust plastic housing
    All non-ex applications
    Design8x Memosens input, 2 to 8x current output,
    Alarmrelay, 2x relay, SD card for software update and copy & paste of setup
    MaterialHousing base: PC-FR
    Housing seal EPDM
    Dimension237 x 194 x 162 mm
    9.33 x 7.64 x 6.38 inch
    Process temperature-20 to 55 °C (0 to 130 °F)
    Ingress protectionIP66 / IP67
    Input1 to 8x Memosens digital input
    2x 0/4 to 20mA Input optional
    2 to 4x Digital input optional
    Output / communication2 to 8x 0/4 to 20 mA current outputs, alarmrelay
    4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
    Additional certificationsEAC, cCSAus
    Measuring principleConductive
    ApplicationModular 4 wire controller
    Multichannel: 1 to 8 digital channels for Memosens protocol
    Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
    8 sensors connectable in any combination
    Functionality modular extendable at any time
    Plug and play for modules and sensors
    CharacteristicRobust plastic housing
    All non-ex applications
    Design8x Memosens input, 2 to 8x current output,
    Alarmrelay, 2x relay, SD card for software update and copy & paste of setup
    MaterialHousing base: PC-FR
    Housing seal EPDM
    Dimension237 x 194 x 162 mm
    9.33 x 7.64 x 6.38 inch
    Ingress protectionIP66 / IP67
    Input1 to 8x Memosens digital input
    2x 0/4 to 20mA Input optional
    2 to 4x Digital input optional
    Output / communication2 to 8x 0/4 to 20 mA current outputs, alarmrelay
    4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
    Additional certificationsEAC, cCSAus
    Measuring principleAmperometric oxygen measurement
    ApplicationModular 4 wire controller
    Multichannel: 1 to 8 digital channels for Memosens protocol
    Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
    8 sensors connectable in any combination
    Functionality modular extendable at any time
    Plug and play for modules and sensors
    CharacteristicRobust plastic housing
    All non-ex applications
    Design8x Memosens input, 2 to 8x current output,
    Alarmrelay, 2x relay, SD card for software update and copy & paste of setup
    MaterialHousing base: PC-FR
    Housing seal EPDM
    Dimension237 x 194 x 162 mm
    9.33 x 7.64 x 6.38 inch
    Process temperature-20 to 55 °C (0 to 130 °F)
    Input1 to 8x Memosens digital input
    2x 0/4 to 20mA Input optional
    2 to 4x Digital input optional
    Output / communication2 to 8x 0/4 to 20 mA current outputs, alarmrelay
    4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
    Additional certificationsEAC, cCSAus
    Measuring principleFree chlorine
    ApplicationModular 4 wire controller
    Multichannel: 1 to 8 digital channels for Memosens protocol
    Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
    8 sensors connectable in any combination
    Functionality modular extendable at any time
    Plug and play for modules and sensors
    CharacteristicRobust plastic housing
    All non-ex applications
    Design8x Memosens input, 2 to 8x current output,
    Alarmrelay, 2x relay, SD card for software update and copy & paste of setup
    MaterialHousing base: PC-FR
    Housing seal EPDM
    Dimension237 x 194 x 162 mm
    9.33 x 7.64 x 6.38 inch
    Process temperature-20 to 55 °C (0 to 130 °F)
    Input1 to 8x Memosens digital input
    2x 0/4 to 20mA Input optional
    2 to 4x Digital input optional
    Output / communication2 to 8x 0/4 to 20 mA current outputs, alarmrelay
    4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
    Additional certificationsEAC, cCSAus
    Measuring principleSingle beam scattered light
    ApplicationModular 4 wire controller
    Multichannel: 1 to 8 digital channels for Memosens protocol
    Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
    8 sensors connectable in any combination
    Functionality modular extendable at any time
    Plug and play for modules and sensors
    CharacteristicRobust plastic housing
    All non-ex applications
    Design8x Memosens input, 2 to 8x current output,
    Alarmrelay, 2x relay, SD card for software update and copy & paste of setup
    MaterialHousing base: PC-FR
    Housing seal EPDM
    Dimension237 x 194 x 162 mm
    9.33 x 7.64 x 6.38 inch
    Process temperature-20 to 55 °C (0 to 130 °F)
    Ingress protectionIP66 / IP67
    Input1 to 8x Memosens digital input
    2x 0/4 to 20mA Input optional
    2 to 4x Digital input optional
    Output / communication2 to 8x 0/4 to 20 mA current outputs, alarmrelay
    4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
    Additional certificationsEAC, cCSAus
    Measuring principlePotentiometric / ISE
    CharacteristicRobust plastic housing
    All non-ex applications
    Process temperature-20 to 55 °C (0 to 130 °F)
    ApplicationModular 4 wire controller
    Multichannel: 1 to 8 digital channels for Memosens protocol
    Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
    8 sensors connectable in any combination
    Functionality modular extendable at any time
    Plug and play for modules and sensors
    Output / communication2 to 8x 0/4 to 20 mA current outputs, alarmrelay
    4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
    Input1 to 8x Memosens digital input
    2x 0/4 to 20mA Input optional
    2 to 4x Digital input optional
    Measuring principlePotentiometric
    ApplicationWater and wastewater, paper, food and beverages, solids, primaries, power stations, utilities
    InstallationComplete automated cleaning system
    CharacteristicFully automated cleaning system with weekly programmable cleaning and different security functions
    DesignFully automated cleaning system in combination with Liquiline CM44x
    MaterialBottom part of housing: PC-FR
    Cover: PC-FR
    Housing seal: EPDM
    Dimension237 x 194 x 162 mm (l x h x w)
    9.33 x 7.64 x 6.38 inch (l x h x w)
    Process temperatureAmbient temperature range: -10 to 45 °C (10 to 113 °F)