Endress+Hauser 71537838 1-/2-channel transmitter bundle with 4-wire field meter

Write a Review

REQUEST A QUOTE

Endress+Hauser 71537838 1-/2-channel transmitter bundle with 4-wire field meter
  • You have an installed base with 4-wire devices and still want to benefit from the advantages of the Liquiline Compact CM72 2-wire transmitter (compact design, Memosens technology, use in hazardous areas, safety against operating errors)? Then this bundle is just right for you, as the RIA46 field meter powers up to two CM72 devices simultaneously. This allows you to set up two CM72 measuring points for pH, ORP, oxygen or conductivity sensors with Memosens technology in your 4-wire environment.
    Use the CM72 2-wire transmitter in a 4-wire environment

    Thanks to its integrated loop power supply, the RIA46 4-wire field meter is able to power one or even two 2-wire transmitters of the Liquiline CM72 series. This allows you to perfectly use the compact and robust field transmitter with your 4-wire infrastructure.

    Transmitter with Memosens technology

    The Liquiline Compact CM72 transmitter can accommodate pH, ORP, conductivity or oxygen sensors (depending on the configuration in the ordering process). Thanks to Memosens technology and the automatic sensor recognition, you can replace worn sensors within seconds.

    Visual indication of status diagnostics

    The CM72 transmitter is equipped with a red/green LED that permanently displays the diagnostic results of the transmitter and the connected sensor, thus enabling a quick and easy status check on-site.

    Suitable for hazardous areas

    With its international explosion protection approvals, such as IECEx, ATEX, and CSA, the Liquiline Compact CM72 is suitable for hazardous area use. Therefore, it is possible to mount the CM72 in a hazardous area even if the RIA46 is installed in a non-hazardous area.

    Measuring principlePotentiometric
    ApplicationAll sectors, supporting all sensors with the blue Memosens plug-in head, enviromental sector
    InstallationConnection of digital sensors with Memosens-Protocol
    CharacteristicLiquiline CM72 is a fixed configured two-wire transmitter for all areas of process engineering
    Measurement rangepH Sensor: 0 to 14 pH
    DesignPeek housing
    MaterialHousing, cover: Peek 151
    Strain relief: EPDM
    Axial ring: Peek 450 G
    DimensionDiameter: 18.95 mm (0.75 inch)
    Length: 114.7 mm (4.52 inch)
    ConnectionConnection of digital sensors with Memosens-Protocol
    Ingress protectionIP67, IP68, NEMA Type 6
    InputOne channel transmitter
    Output / communication4 to 20 mA
    Additional certificationsCE, CSA C/US GP
    Measuring principlePotentiometric
    ApplicationAll sectors, supporting all sensors with the blue Memosens plug-in head, enviromental sector
    InstallationConnection of digital sensors with Memosens-Protocol
    CharacteristicLiquiline CM72 is a fixed configured two-wire transmitter for all areas of process engineering
    Measurement rangeORP sensors: -1500 mV to 1500 mV
    DesignPeek housing
    MaterialHousing, cover: Peek 151
    Strain relief: EPDM
    Axial ring: Peek 450 G
    DimensionDiameter: 18.95 mm (0.75 inch)
    Length: 114.7 mm (4.52 inch)
    ConnectionConnection of digital sensors with Memosens-Protocol
    Ingress protectionIP67, IP68, NEMA Type 6
    InputOne channel transmitter
    Output / communication4 to 20 mA
    Measuring principlePotentiometric
    ApplicationAll sectors, supporting all sensors with the blue Memosens plug-in head, enviromental sector
    InstallationConnection of digital sensors with Memosens-Protocol
    CharacteristicLiquiline CM72 is a fixed configured two-wire transmitter for all areas of process engineering
    Measurement rangeConductivity sensors: 0 to 500 mS/cm
    DesignPeek housing
    MaterialHousing, cover: Peek 151
    Strain relief: EPDM
    Axial ring: Peek 450 G
    DimensionDiameter: 18.95 mm (0.75 inch)
    Length: 114.7 mm (4.52 inch)
    ConnectionConnection of digital sensors with Memosens-Protocol
    Ingress protectionIP67, IP68, NEMA Type 6
    InputOne channel transmitter
    Output / communication4 to 20 mA
    Measuring principlePotentiometric
    ApplicationAll sectors, supporting all sensors with the blue Memosens plug-in head, enviromental sector
    InstallationConnection of digital sensors with Memosens-Protocol
    CharacteristicLiquiline CM72 is a fixed configured two-wire transmitter for all areas of process engineering
    Measurement rangeOxygen sensors: 0 to 20 mg/l
    DesignPeek housing
    MaterialHousing, cover: Peek 151
    Strain relief: EPDM
    Axial ring: Peek 450 G
    DimensionDiameter: 18.95 mm (0.75 inch)
    Length: 114.7 mm (4.52 inch)
    ConnectionConnection of digital sensors with Memosens-Protocol
    InputOne channel transmitter
    Output / communication4 to 20 mA
    Measuring principleIndicators with control unit
    Measuring principleField meter with control unit
    FunctionDisplay
    Loop Power Supply
    Transmitter Functionality
    Barrier
    Signal Isolation
    Calculation
    Limit Alarm
    DisplayMulticolor backlight LCD
    White/black/yellow
    Bargraph
    Unit
    TAG
    Alarm warning in plain text
    Power Supply20...250V AC/DC
    Input2 x universal (U, I, R, RTD, TC)
    Output2 x analogue output (I, U) 1 x loop power supply
    Output2 x analogue output (I, U) 1 x loop power supply
    Software functionsLinearization
    Minimum value per channel
    Maximum value per channel
    Calculation
    Band value monitoring
    CertificatesATEX II(1)GD [Ex ia] IIC
    CSA General Purpose
    CSA AIS, NI/I/2/ABCDEFG/T4
    FM AIS, NI/I/2/ABCDEFG/T4
    TIIS [Ex ia] IIC
    NEPSI [Ex ia] IIC
    UK II(1)G [Ex ia Ga] IIC, II(1)D [Ex ia Da] IIIC
    SIL2
    Panel mountingfield
    Measuring principleDisplay
    FunctionDisplay
    Loop Power Supply
    Transmitter Functionality
    Barrier
    Signal Isolation
    Calculation
    Limit Alarm
    CertificationATEX II (1) GD [Ex ia] 4C
    CSA AIS
    NI/I/2 ABCDEFG/T4
    FM AIS
    NI/I/2 ABCDEFG/T4
    UR C/US
    Input2 x universal (U, I, R, RTD, TC)
    Output2 x analogue output (I, U)
    1 x loop power supply
    Relay output2 x changeover contact
    1 x open collector
    Auxiliary power supply / Loop power supply20...250V AC/DC
    Dimensions (wxhxd)Field housing:
    199 x 133 x 96 mm
    (7.83" x 5.24" x 3.78")
    SoftwareLinearization
    Minimum value per channel
    Maximum value per channel
    Calculation
    Band value monitoring
    Operation3 keys
    Interface CDI to USB at PC + configuration software FieldCare
    DisplayMulticolor backlight LCD
    White/black/yellow
    Bargraph
    Unit
    TAG
    Alarm warning in plain text
    Returns Policy