For applications where the thermometer is installed in locations with difficult access, like e.g. on top of tanks or in installation shafts, the temperature transmitter can be separated from the thermometer and istalled in an area of easy access or a cabinet. A local display can offer additional value for operation and maintenance. | |
Comfortable handling and read-out |
|
---|---|
Measuring principle | Resistance Temperature Detector |
Characteristic / Application | metric style modular temperature assembly universal range of application suitable for hazardous areas with neck or QuickNeck incl. thermowell / protection tube (metal) or to be installed into thermowell can be used with StrongSens, QuickSens insert for fast response times |
Thermowell / protection tube | welded protection tube or to be used with thermowell |
Insert / probe | mineral insulated (MI), flexible |
Outer diameter protection tube / Insert | Thermowell: 9x1,25 mm 11x2 mm 12x2,5 mm 14x2 mm 16x3,5 1/4" SCH80 1/2" SCH80 1/2" SCH40 |
Max. immersion length on request | up to 4.500,0 mm (177'') |
Material protection tube/ thermowell | 316 (1.4401) 316L (1.4404) 316Ti (1.4571) Alloy 600 (2.4816) Alloy C276 (2.4819) Alloy 446 (1.4749) Alloy 321 (1.4541) Sheath PTFE Sheath Tantal |
Process connection | Male thread: G3/8, G1/2", G3/4", G1" NPT1/2", NPT3/4", NPT 1" M14x1.5, M18x1.5, M20x1.5, M27x2, M33x2 R1/2", R3/4" Female thread: M20x1.5, M24x1.5 NPT1/2" Cap-nut: M20x1.5, G1/2", G3/4" Compression fitting: NPT1/2", G1/2", G1" Flange: DN15 PN40 B1, C DN25 PN20, PN40, PN100 B1, B2, C DN40 PN40 B1 DN50 PN40 B1 ASME 1" 150 RF ASME 1" 300 RF ASME 1 1/2" 150 RF ASME 2" 150 RF ASME 2" 300 RF |
Tip shape | straight reduced tapered optimized for quick response times |
Surface roughness Ra | < 0.76 μm (0.03 μin) |
Operating temperature range | PT100 TF StrongSens: -50 °C ...500 °C (-58 °F ...932 °F) PT100 QuickSensTF: -50 °C …200 °C (-58 °F …392 °F) PT100 WW: -200 °C ...600 °C (-328 °F ...1.112 °F) PT100 TF: -50 °C ...400 °C (-58 °F ...752 °F) Typ K: max. 1.100 °C (max. 2.012 °F) Typ J: max. 800 °C (max. 1.472 °F) Typ N: max. 1.100 °C (max. 2.012 °F) |
Max. process pressure (static) | depending on the configuration up to 100 bar |
Accuracy | Class AA acc. to IEC 60751 Class A acc. to IEC 60751 Class B acc. to IEC 60751 Class special or standard acc. to ASTM E230 Class 1 or 2 acc. to IEC 60584-2 |
Response time | fastest response time with thermowell t90 starting at below 10 s depending on configuration |
Integration head transmitter | yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS) |
Ex - approvals | ATEX ATEX IECEx NEPSI IECEx EAC Ex CSA C/US INMETRO |
Certification | SIL, MID, DNV/GL |
Measuring principle | Head transmitter |
Input | 2 x RTD, TC, Ohm, mV |
Output | 1 x analog 4...20 mA / HART |
Auxiliary power supply | 11...42 V DC (head transmitter) 12...42 V DC (Din rail device) 11/12...30 V DC (Ex ia) |
Communication | HART-protocol |
Installation | Terminal head form B, DIN-Rail housing or field mount housing |
Accuracy | (Pt100, -50...200 °C) <= 0,1 K (Pt100, -58...392 °F) <= 0,18 °F |
Galvanic isolation | yes |
Certification | ATEX II1G Ex ia IIC T4/T5/T6 ATEX II3G Ex ic IIC T6 ATEX II2D Ex tb IIIC Db ATEX II3D Ex tc IIIC Dc ATEX II3G Ex nA IIC T6 ATEX II1G Ex ia IIC T6, II3D ATEX II3G Ex nA IIC T6, II3D ATEX II2G Ex d T6, II2D Ex tb IIIC CSA C/US General Purpose CSA IS, NI I / 1+2/A-D CSA XP, NI, DIP I, II, III/1+2/A-G FM IS,NI I / 1+2/A-D FM XP, NI, DIP I, II, III/1+2/A-G EAC Ex ia IIC T6 Ga EAC Ex d IIC T6 Gb EAC Ex ia IIC T6, II3D IECEx Ex ia IIC T4/T5/T6 IECEx Ex tb IIIC Db IECEx Ex nA II T4/T5/T6 IECEx Ex d T6 Gb, Ex tb IIIC Db INMETRO Ex ia [ia Ga] IIC T6 Gb INMETRO Ex d T6 Gb, Ex tb IIIC Db NEPSI Ex ia IIC T6 Ga NEPSI Ex d IIC T6 Gb NEPSI Ex nA IIC T6 Gc TIIS Ex ia IIC T6 TIIS Ex nA II T6 UK II1G Ex ia IIC T6 Ga UK II2D Ex tb IIIC Db UK II3D Ex tc IIIC Dc UK II1G Ex ia IIC T6 Ga, II3D Ex ia IIIC Dc UK II3G Ex nA IIC Gc, II3D Ex tc IIIC Dc UK II2G Ex db IIC T6 Gb, II2D Ex tb IIIC Db ATEX IECEx II1G Ex ia IIC T6 Ga FM+CSA IS, NI I/1+2/A-D |