Max. measurement error | Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.) |
---|---|
Measuring range | 20 to 733501 kg/h (44 to 1669340 lb/h) |
Medium temperature range | -40 °C to +180°C (-40 °F to +356°F) |
Max. process pressure | -0.5 to 20 bar_g (-7.25 to 290 psi_g) |
Wetted materials | Materials for insertion tube Stainless steel, 1.4404 (316/316L) Process connections, process coupling Stainless steel, 1.4404 (316/316L) Sensing element Unidirectional Stainless steel, 1.4404 (316/316L) Alloy C22, 2.4602 (UNS N06022); Bidirectional Stainless steel, 1.4404 (316/316L) Reverse flow detection Stainless steel, 1.4404 (316/316L) Clamping rings PEEK PVDF 1.4404 (316/316L) Flat ring seal EPDM FKM |
Measuring principle | Thermal |
Product headline | Insertion flowmeter with long-term stability as remote version with up to 4 I/Os. Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof. Measurement of utility and process gases as well as gas mixtures in circular piping or rectangular ducts. |
Sensor features | High level of process control – premium measurement accuracy and repeatability. Reliable monitoring – detection of process disturbances and reverse flow. Flexible installation – suitable for large dimensional range and circular pipes or rectangular ducts. Insertion version for DN 80 to 1500 (3 to 60"). Bidirectional measurement; high measuring performance. Patented drift-free sensor with SIL 2. |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal diameter range | DN 80 to 1500 (3 to 60") |
Wetted materials | Materials for insertion tube Stainless steel, 1.4404 (316/316L) Process connections, process coupling Stainless steel, 1.4404 (316/316L) Sensing element Unidirectional Stainless steel, 1.4404 (316/316L) Alloy C22, 2.4602 (UNS N06022); Bidirectional Stainless steel, 1.4404 (316/316L) Reverse flow detection Stainless steel, 1.4404 (316/316L) Clamping rings PEEK PVDF 1.4404 (316/316L) Flat ring seal EPDM FKM |
Measured variables | Massflow, temperature, standard volume flow, volume flow, Free air delivery, velocity, heat flow, energy flow, density |
Max. measurement error | Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.) |
Measuring range | 20 to 733501 kg/h (44 to 1669340 lb/h) |
Max. process pressure | -0.5 to 20 bar_g (-7.25 to 290 psi_g) |
Medium temperature range | -40 °C to +180°C (-40 °F to +356°F) |
Ambient temperature range | -40 to 60°C (-40 to 140°F) Optional: Transmitter: -50 to 60°C (-50 to 140°F), Sensor: -60 to 60°C (-60 to 140°F) |
Transmitter housing material | Aluminium, AlSi10Mg, coated Polycarbonate |
Degree of protection | IP66/67, Type 4X enclosure Sensor: IP68, Type 6P (optional) |
Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available |
Outputs | 4-20 mA HART (active/passive) 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Relay output |
Inputs | Status input 4-20 mA input |
Digital communication | HART, Modbus RS485 |
Power supply | DC 24V AC 100 to 240V |
Hazardous area approvals | ATEX, cCSAus, IECEx, NEPSI, JPN, UK Ex, EAC |
Product safety | CE, C-tick |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a |
Pressure approvals and certificates | CRN |
Material certificates | 3.1 material NACE MR0175/MR0103 |