Endress+Hauser
Endress+Hauser 6AAB Proline t-mass A 150 thermal mass flowmeter
REQUEST A QUOTE
Max. measurement error | 3 % o.r. 4 % o.r. 5 % o.f.s. (depending on chosen option of ordering feature "Calibration flow") |
---|---|
Measuring range | 0.5 to 910 kg/h (1.1 to 2002 lb/h) 0.5 to 1365 kg/h (1.1 to 3003 lb/h) (for air, depending on chosen option of ordering feature "Calibration flow") |
Medium temperature range | –40 to +100 °C (–40 to +212 °F) |
Max. process pressure | PN 40, Class 300 |
Wetted materials | Transducer: 1.4404 (316L) Insertion tube: 1.4404 (316L) Measuring tube: 1.4404 (316L); 1.4435 (316L) Connection: 1.4404 (F316/F316L); 1.4404 (316L); 1.4435 (316L) |
Measuring principle | Thermal |
Product headline | The flowmeter for cost-effective measurement and easy monitoring of utility gases. Suitable for air, nitrogen, carbon dioxide and argon in small line sizes. |
Sensor features | Optimal process monitoring – easy measurement even at low pressures and flow velocities. Cost-effective measurement – easy installation, negligible pressure loss and maintenance-free. Reliable flow trending – multivariable measurement. Inline version: DN 15 to 50 (½ to 2"). Process pressure up to PN 40, Class 300. A variety of process connections available. |
Transmitter features | Fast and efficient commissioning – guided operating menus. High plant availability – self‐diagnostics and error monitoring. Automatic recovery of data for servicing. Device in compact version with DC 24 V power supply. 4-20 mA HART, pulse/frequency/switch output. Compact and robust transmitter. |
Nominal diameter range | DN 15 to 50 (½ to 2") |
Wetted materials | Transducer: 1.4404 (316L) Insertion tube: 1.4404 (316L) Measuring tube: 1.4404 (316L); 1.4435 (316L) Connection: 1.4404 (F316/F316L); 1.4404 (316L); 1.4435 (316L) |
Measured variables | Mass flow, temperature, corrected volume flow, FAD volume flow |
Max. measurement error | 3 % o.r. 4 % o.r. 5 % o.f.s. (depending on chosen option of ordering feature "Calibration flow") |
Measuring range | 0.5 to 910 kg/h (1.1 to 2002 lb/h) 0.5 to 1365 kg/h (1.1 to 3003 lb/h) (for air, depending on chosen option of ordering feature "Calibration flow") |
Max. process pressure | PN 40, Class 300 |
Medium temperature range | –40 to +100 °C (–40 to +212 °F) |
Ambient temperature range | –40 to +60 °C (–40 to +140 °F) |
Transmitter housing material | AlSi10Mg, coated |
Degree of protection | IP66/67, type 4X enclosure |
Display/Operation | 4‐line display with push Buttons Configuration via local display and operating tools possible |
Outputs | 4‐20 mA HART (active) Pulse/frequency/switch output (passive) |
Inputs | Status input |
Digital communication | HART |
Power supply | DC 18 to 30 V |
Hazardous area approvals | ATEX, IECEx, cCSAus |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR |
Pressure approvals and certificates | PED, CRN |
Returns Policy