Endress+Hauser
Endress+Hauser 5WBB Proline Promag W 10 electromagnetic flowmeter
REQUEST A QUOTE
Max. measurement error | Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s) |
---|---|
Measuring range | 0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d) |
Medium temperature range | Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) Liner material PTFE: –20 to +90 °C (–4 to +194°F) |
Max. process pressure | PN 40, Class 300, 20K |
Wetted materials | Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) Liner material PTFE: –20 to +90 °C (–4 to +160 °F) Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022) |
Measuring principle | Electromagnetic |
Product headline | Flowmeter for basic water and wastewater applications with easy-to-use operation concept. Reliable measurement at constant accuracy with 0 x DN inlet run without pressure loss. Suitable for elementary measurement tasks such as raw water intake. |
Sensor features | Flexible engineering – sensor with fixed or lap-joint process connections. Application fitness – EN ISO 12944 corrosion protection for underground or underwater installation. Improved plant availability – sensor compliant with industry-specific requirements. International drinking water approvals. Degree of protection IP68 (Type 6P enclosure). International drinking water approvals. Installation length: DVGW/ISO conform. |
Transmitter features | Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology. System integration with HART, Modbus RS485. Flexible operation with app and optional display. |
Nominal diameter range | DN 25 to 3000(1 to 120") |
Wetted materials | Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) Liner material PTFE: –20 to +90 °C (–4 to +160 °F) Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022) |
Measured variables | Volume flow, conductivity, mass flow |
Max. measurement error | Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s) |
Measuring range | 0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d) |
Max. process pressure | PN 40, Class 300, 20K |
Medium temperature range | Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) Liner material PTFE: –20 to +90 °C (–4 to +194°F) |
Ambient temperature range | -40 to 60°C (-40 to 140°F) |
Sensor housing material | DN 25 to 300 (1 to 12"): AlSi10Mg, coated DN 350 to 2000 (14 to 78"): Carbon steel with protective varnish |
Transmitter housing material | Polycarbonat; AlSi10Mg, coated |
Degree of protection | Compact version: IP66/67, type 4X enclosure Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP68, type 6P enclosure, with protective varnish according to EN ISO 12944 C5-M/Im1/Im2/Im3 |
Display/Operation | LCD display with touch & auto rotate |
Outputs | 4-20 mA HART (active/passive), Pulse/frequency/switch output Modbus RS485, 4-20 mA |
Digital communication | HART, MODBUS RS485 |
Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | CSA, GP, KC |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Pressure approvals and certificates | CRN, PED |
Material certificates | 3.1 material |
Hygienic approvals and certificates | Drinking water approvals: ACS, KTW/W270, NSF 61, WRAS BS 6920 |
Returns Policy