Endress+Hauser 5W8C Proline Promag W 800 electromagnetic flowmeter

Write a Review

REQUEST A QUOTE

Endress+Hauser 5W8C Proline Promag W 800 electromagnetic flowmeter
Max. measurement errorVolume flow: ±0.5 % o.r. ± 2 mm/s (±0.5 % o.r. ± 0.08 in/s)
Measuring range9 dm³/min to 22500 m³/h (2.5 to 100000 gal/min)
Medium temperature rangeLiner material hard rubber: 0 to +70 °C (+32 to +158 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: -20 to 90°C (–4 to +194 °F)
Max. process pressurePN 40, Class 300, 20K
Wetted materialsLiner: polyurethane; PTFE; hard rubber
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)
Measuring principleElectromagnetic
Product headlineBattery-powered flowmeter with EN ISO 12944 corrosion protection & intelligent energy efficient mode.
For direct underground installation or permanent underwater use.
Certified sensor for the most demanding water and wastewater applications.
Sensor featuresSecure, reliable long‐term operation – robust and completely welded sensor. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
International drinking water approvals. Degree of protection IP68 (Type 6P enclosure).
Transmitter featuresSecure data storage and transmission – worldwide
encrypted communication over the mobile network . Convenient commissioning and operation – device
access via Bluetooth using intuitive SmartBlue app. Integrated verification – Heartbeat Technology.
Transmitter housing made of durable polycarbonate. Battery lifetime up to 15 years. Measuring intervals can be adapted individually.
Nominal diameter rangeDN 25 to 900 (1 to 36")
Wetted materialsLiner: polyurethane; PTFE; hard rubber
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)
Measured variablesVolume flow
Max. measurement errorVolume flow: ±0.5 % o.r. ± 2 mm/s (±0.5 % o.r. ± 0.08 in/s)
Measuring range9 dm³/min to 22500 m³/h (2.5 to 100000 gal/min)
Max. process pressurePN 40, Class 300, 20K
Medium temperature rangeLiner material hard rubber: 0 to +70 °C (+32 to +158 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: -20 to 90°C (–4 to +194 °F)
Ambient temperature rangeFlange material carbon steel: –10 to +60 °C (14 to +140 °F)
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)
Sensor housing materialDN 25 to 300 (1 to 12"): AlSi10Mg, coated
DN 350 to 900 (14 to 36"): Carbon steel with protective varnish
Transmitter housing materialPolycarbonat
Degree of protectionCompact version: IP66/67, type 4X enclosure and IP68, type 6P enclosure
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP68, type 6P enclosure, with protective varnish according to EN ISO 12944 C5-M/Im1/Im2/Im3
Display/Operation4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible; Remote data access via mail and SMS
Outputs3x Pulse/switch output (passive); Modbus RS485
InputsStatus input
Digital communicationLTE Cat M1; LTE Cat NB1; LTE Cat NB2; GPRS; EGPRS
Power supplyInternal:
Batteries per DC 3.6 V External:
AC 85 to 265 V (47 to 63 Hz) / DC 19 to 30 V
Hazardous area approvalsCSA, GP
Product safetyCE Marking, EAC Marking, UKCA Marking
Metrological approvals and certificatesCalibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Custody transfer according to MI‐001
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificatesCRN, PED
Hygienic approvals and certificatesDrinking water approval: ACS, KTW/W270, NSF 61, WRAS BS 6920
Returns Policy