Max. measurement error | Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s) Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec |
---|---|
Measuring range | 0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d) |
Medium temperature range | Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) Liner material PTFE: –20 to +90 °C (–4 to +194 °F) |
Max. process pressure | PN 40, Class 300, 20K |
Wetted materials | Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) Liner material PTFE: –20 to +90 °C (–4 to +194 °F) Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum |
Measuring principle | Electromagnetic |
Product headline | Versatile standard flowmeter for the water and wastewater industry. Reliable measurement at constant accuracy with 0 x DN inlet run and no pressure loss. Ideal for water measurement, e.g. drinking water, utility water and industrial/municipal wastewater. |
Sensor features | Flexible engineering – sensor with fixed or lap-joint process connections. Application fitness – EN ISO 12944 corrosion protection for underground or underwater installation. Improved plant availability – sensor compliant with industry-specific requirements. International drinking water approvals. Degree of protection IP68 (Type 6P enclosure). Approved for custody transfer to MI-001/OIML R49. |
Transmitter features | Safe operation – no need to open the device due to display with touch control, background lighting. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. Transmitter housing made of durable polycarbonate or aluminium. WLAN access. Integrated data logger: measured values monitoring. |
Nominal diameter range | DN 25 to 3000(1 to 120") |
Wetted materials | Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) Liner material PTFE: –20 to +90 °C (–4 to +194 °F) Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum |
Measured variables | Volume flow, conductivity, mass flow |
Max. measurement error | Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s) Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec |
Measuring range | 0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d) |
Max. process pressure | PN 40, Class 300, 20K |
Medium temperature range | Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) Liner material PTFE: –20 to +90 °C (–4 to +194 °F) |
Ambient temperature range | Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) |
Sensor housing material | DN 25 to 300 (1 to 12"): AlSi10Mg, coated DN 25 to 2000 (1 to 78"): Carbon steel with protective varnish Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): Polycarbonate |
Transmitter housing material | Polycarbonat; AlSi10Mg, coated |
Degree of protection | Compact version: IP66/67, type 4X enclosure Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP68, type 6P enclosure, with protective varnish according to EN ISO 12944 C5‐M/Im1/Im2/Im3 Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation | 4‐line backlit display with touch control (operation from outside) Configuration via local display, web browser and operating tools possible |
Outputs | 3 ouputs: 0‐20 mA/4‐20 mA HART (active) Pulse/frequency/switch output (passive) Pulse/frequency output (passive) Switch output (passive) |
Inputs | Status input |
Digital communication | HART, PROFIBUS DP, EtherNet/IP, Modbus RS485 |
Power supply | AC 100…240 V / AC/DC 24 V |
Hazardous area approvals | cCSAus |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR Custody transfer according to MI‐001 or OIML R49 (optional class I in combination with 0DN inlet run) |
Pressure approvals and certificates | CRN |
Material certificates | 3.1 material |
Hygienic approvals and certificates | Drinking water approval: ACS, KTW/W270, NSF 61, WRAS BS 6920 |