Max. measurement error | Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s) |
---|---|
Measuring range | 4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min) |
Medium temperature range | Liner material PFA: –20 to +150 °C (–4 to +302 °F) Liner material PTFE: –40 to +130 °C (–40 to +266 °F) |
Max. process pressure | PN 40, Class 300, 20K |
Wetted materials | Liner: PFA; PTFE Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium |
Measuring principle | Electromagnetic |
Product headline | Flowmeter for basic process applications with easy-to-use operation concept. Dedicated to chemical and process applications with corrosive liquids. |
Sensor features | Diverse applications – wide variety of wetted materials. Energy-saving flow measurement – no pressure loss due to cross section constriction. Maintenance-free – no moving parts. Nominal diameter: max. DN 600 (24"). All common Ex approvals. Liner made of PTFE or PFA. |
Transmitter features | Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology. System integration with HART, Modbus RS485. Flexible operation with app and optional display. |
Nominal diameter range | DN 15 to 600 (½ to 24") |
Wetted materials | Liner: PFA; PTFE Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium |
Measured variables | Volume flow, conductivity, mass flow |
Max. measurement error | Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s) |
Measuring range | 4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min) |
Max. process pressure | PN 40, Class 300, 20K |
Medium temperature range | Liner material PFA: –20 to +150 °C (–4 to +302 °F) Liner material PTFE: –40 to +130 °C (–40 to +266 °F) |
Ambient temperature range | Flange material carbon steel: –10 to +60 °C (+14 to +140 °F) Flange material stainless steel: –40 to +60 °C (–40 to +140 °F) |
Sensor housing material | DN 15 to 300 (½ to 12""): AlSi10Mg, coated DN 350 to 600 (14 to 24""): Carbon steel with protective varnish |
Transmitter housing material | AlSi10Mg, coated |
Degree of protection | Standard: IP66/67, Type 4X enclosure |
Display/Operation | 2.4" LCD display with touch & auto rotate; Configuration and operation via SmartBlue App (Bluetooth) possible |
Outputs | 4-20 mA HART (active/passive), Pulse/frequency/switch output Modbus RS485, 4-20 mA |
Digital communication | HART, MODBUS RS485 |
Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, EAC, NEPSI, INMETRO, KC, JPN, UK Ex |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Pressure approvals and certificates | PED, CRN |
Material certificates | 3.1 material |
Hygienic approvals and certificates | Driking water approvals: ACS; NSF61, WRAS |