Endress+Hauser 5P2B Proline Promag P 200 electromagnetic flowmeter

Write a Review

REQUEST A QUOTE

Endress+Hauser 5P2B Proline Promag P 200 electromagnetic flowmeter

Max. measurement errorVolume flow: ±0.5 % o.r. ± 2 mm/s (0.08 in/s)
Measuring range4 dm3/min to 1100 m3/h (1 to 4850 gal/min)
Medium temperature rangeLiner material PFA: –20 to +150 °C (–4 to +302 °F)
Liner material PTFE: –40 to +130 °C (–40 to +266 °F)
Max. process pressurePN 40, Class 300, 20K
Wetted materialsLiner: PFA; PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum
Measuring principleElectromagnetic
Product headlineThe flowmeter for highest medium temperatures with genuine loop-powered technology.
Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.
Sensor featuresDiverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Nominal diameter: max. DN 200 (8"). All common Ex approvals. Liner made of PTFE or PFA.
Transmitter featuresConvenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
Nominal diameter rangeDN 15 to 200 (½ to 8")
Wetted materialsLiner: PFA; PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum
Measured variablesVolume flow, mass flow
Max. measurement errorVolume flow: ±0.5 % o.r. ± 2 mm/s (0.08 in/s)
Measuring range4 dm3/min to 1100 m3/h (1 to 4850 gal/min)
Max. process pressurePN 40, Class 300, 20K
Medium temperature rangeLiner material PFA: –20 to +150 °C (–4 to +302 °F)
Liner material PTFE: –40 to +130 °C (–40 to +266 °F)
Ambient temperature rangeFlange material carbon steel: –10 to +60 °C (+14 to +140 °F)
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)
Sensor housing materialAlSi10Mg, coated
Transmitter housing materialAlSi10Mg, coated
Degree of protectionIP66/67, type 4X enclosure
Display/Operation4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs4‐20 mA HART (passive)
Pulse/frequency/switch output (passive)
InputsNone
Digital communicationHART, PROFIBUS PA, FOUNDATION Fieldbus
Power supplyDC 18 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
Hazardous area approvalsATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, JPN, UK Ex
Other approvals and certificates
Product safetyCE, C-Tick
Functional safetyFunctional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificatesCalibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificatesCRN, PED
Material certificates3.1 material
Hygienic approvals and certificatesDrinking water approvals: ACS, NSF 61
Returns Policy