Endress+Hauser 5HBB Proline Promag H 10 electromagnetic flowmeter

Write a Review

REQUEST A QUOTE

Endress+Hauser 5HBB Proline Promag H 10 electromagnetic flowmeter
Max. measurement errorVolume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Measuring range0.06 dm³/min to 600 m³/h (0.015 to 2650 gal/min)
Medium temperature range–20 to +150 °C (–4 to +302 °F)
Max. process pressurePN 40, Class 150, 20K
Wetted materialsLiner: PFA
Electrodes: 1.4435 (316L); Alloy C22
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
Seals: aseptic molded seal (EPDM, FKM, silicone)
Measuring principleElectromagnetic
Product headlineFlowmeter for basic hygienic applications with easy-to-use operation concept.
For applications with sanitary requirements.
Sensor featuresFlexible installation concept – numerous hygienic process connections. Energy-saving flow measurement – no pressure loss due to cross section constriction. Maintenance-free – no moving parts.
Liner made of PFA. Sensor housing made of stainless steel (3-A, EHEDG). Wetted materials CIP-/SIP-cleanable.
Transmitter featuresOptimum usability – operation with mobile devices and SmartBlue app or display with touch screen. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology.
System integration with HART, Modbus RS485. Flexible operation with app and optional display.
Nominal diameter rangeDN 2 to 150 (¹⁄₁₂ to 6")
Wetted materialsLiner: PFA
Electrodes: 1.4435 (316L); Alloy C22
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
Seals: aseptic molded seal (EPDM, FKM, silicone)
Measured variablesVolume flow, temperature, conductivity, mass flow, corrected volume flow, corrected
conductivity
Max. measurement errorVolume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Measuring range0.06 dm³/min to 600 m³/h (0.015 to 2650 gal/min)
Max. process pressurePN 40, Class 150, 20K
Medium temperature range–20 to +150 °C (–4 to +302 °F)
Ambient temperature range–40 to +60 °C (–40 to +140 °F)
Sensor housing material1.4301 (304), corrosion resistant
Transmitter housing materialAlSi10Mg, coated
Degree of protectionStandard: IP66/67, type 4X enclosure
Display/Operation2.4" LCD display with touch & auto rotate; Configuration and operation via SmartBlue App (Bluetooth) possible
Outputs4-20 mA HART (active/passive), Pulse/frequency/switch output
Modbus RS485, 4-20 mA
Digital communicationHART, MODBUS RS485
Power supplyDC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvalsCSA, GP, KC
Metrological approvals and certificatesCalibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificatesPED, CRN
Material certificates3.1 material
Hygienic approvals and certificatesSanitary approval: EHEDG, 3-A, liner and seals acc. to FDA, cGMP