Endress+Hauser
Endress+Hauser 5BH Dosimag electromagnetic flowmeter
REQUEST A QUOTE
Max. measurement error | ±0.25 % o.r. ± 1 to 4 m/s (3.3 to 13 ft/s) ±0.5 % o.r. ± 1 mm/s (0.04 in/s) ±5 % o.r. |
---|---|
Measuring range | 0.14 to 1.66 l/s (0.035 to 0.44 gal/s) |
Medium temperature range | Seal material EPDM: –20 to +130 °C (–4 to +266 °F) Seal material Silicone: –20 to +130 °C (–4 to +266 °F) Seal material Viton: 0 to +150 °C (+32 to +302 °F) |
Max. process pressure | PN 16 |
Wetted materials | Liner: PFA Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022), Tantalum, Platinum |
Measuring principle | Electromagnetic |
Product headline | Flowmeter with hygienic design, highest repeatability and an ultra-compact sensor. For demanding dosing and filling applications. |
Sensor features | High process safety – high measuring accuracy and repeatability in shortest filling time. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts. Wetted materials CIP, SIP cleanable. Nominal diameter: DN 4 to 25 (¹⁄₈ to 1"). Measuring device conform to FDA. |
Transmitter features | Versatile and time-saving wiring – plug connector. Industry-optimized – ultra-compact design. For hygienic requirements – stainless steel housing. Pulse/frequency/switch output, Modbus RS485. Custody transfer approvals (MID, NTEP). Excellent, easily cleanable transmitter. |
Nominal diameter range | DN 4 (⁵⁄₃₂"), 8 (⁵⁄₁₆"), 15 (½"), 25 (1") |
Wetted materials | Liner: PFA Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022), Tantalum, Platinum |
Measured variables | Volume flow |
Max. measurement error | ±0.25 % o.r. ± 1 to 4 m/s (3.3 to 13 ft/s) ±0.5 % o.r. ± 1 mm/s (0.04 in/s) ±5 % o.r. |
Measuring range | 0.14 to 1.66 l/s (0.035 to 0.44 gal/s) |
Max. process pressure | PN 16 |
Medium temperature range | Seal material EPDM: –20 to +130 °C (–4 to +266 °F) Seal material Silicone: –20 to +130 °C (–4 to +266 °F) Seal material Viton: 0 to +150 °C (+32 to +302 °F) |
Ambient temperature range | –40 to +60 °C (–40 to +140 °F) |
Sensor housing material | 1.4308 (304) |
Transmitter housing material | 1.4308 (304) |
Degree of protection | IP66/67, type 4X enclosure |
Display/Operation | No local Operation Configuration via operating tools possible |
Outputs | Pulse/frequency/switch output (passive) |
Inputs | None |
Digital communication | Modbus RS485 |
Power supply | DC 20 to 30 V |
Hazardous area approvals | ATEX, IECEx, cCSAus |
Product safety | CE |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc.to ISO/IEC 17025) NTEP |
Material certificates | 3.1 material |
Hygienic approvals and certificates | Sanitary approval: 3-A, EHEDG, seals acc. to FDA (except EPDM) |
Returns Policy