Wishlist Endress+Hauser Endress+Hauser 1-channel transmitter Liquiline CM14 InputOne-channel-transmitterOutput / communication0/4-20mAIngress protectionFront IP65 , NEMA 4X, Body IP20Measuring principlePotentiometricApplicationWater, waste waterCharacteristic4-wire transmitter with a two-line displayMeasuring principlepH/ORP... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Calibration tool for conductivity sensors Conducal CLY421 Measuring principleConductiveApplicationCalibration of conductivity measuring loops in ultra-pure water applications in the pharmaindustry; calibration of quality-relevant process measurements in the ultra-pure water range up to... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Analog conductivity sensor Indumax CLS54 Measurement range100 µS/cm - 2000 mS/cm Cell constant k: 6,3 1/cmProcess temperatureProcess temperature: -10°C - +125°C(14°F - 257°F)Sterilisation: 150°C/5 bar (max. 60 min.)(302°F / 72.5 psi)Process pressure12 bar(174 psi)/20°C(68°F)8 bar(116... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Analog conductivity sensor Indumax CLS52 Measurement range0.1 to 2000 mS/cmProcess temperatureMax. 125°C (short time up to 140°C)max. 257°F (short time up to 284°F)Process pressureMax. 16 bar at 90 °C(Max. 232 psi at 194 °F)Measuring principleInductiveApplicationFood,... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital conductivity sensor Indumax CLS50D Measurement range2µS/cm to 2000 mS/cmProcess temperaturePEEK: max. 125°C (max. 260 °F)PFA: max. 110°C (max. 230 °F)Process pressurePEEK: max. 21 bar (max. 304.5 psi)PFA: max. 17 bar (max. 246.5 psi)Measuring principleInductiveApplicationChemical... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Analog conductivity sensor Indumax CLS50 Measurement range2µS/cm - 2000 mS/cmProcess temperaturemax. 180°C (PEEK)(356°F)max. 125°C (PFA)(254°F)Process pressuremax. 20 bar (PEEK)(290 psi) max. 16 bar (PFA)(233 psi)Measuring principleInductiveApplicationWaste water, processCharacteristicInductive... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Analog conductivity sensor Condumax CLS21 Measurement rangek=1: 10,0 µS/cm - 20,0 mS/cmProcess temperaturemax. 135°C(max. 275°F)Process pressuremax. 16 bar at 20°С(max. 232psi at 68°F)Measuring principleConductiveApplicationWater, waste water, process, media separation, industrial water... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Analog conductivity sensor Condumax CLS19 Measurement rangek=0,01: 0-20 µS/cmk=0,1: 0-200 µS/cmProcess temperaturemax. 60°Cmax. 140°FProcess pressuremax. 6 bar at 20°C(max.87 psi at 68°F)Measuring principleConductiveApplicationPure and ultrapure waterCharacteristic2-electrode conductivity cell... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Analog conductivity sensor Condumax CLS16 Measurement rangek=0,1: 0,04µS/cm - 500µS/cmProcess temperatureMax. 120°C (150°C/30 min)max. 248°F (302°F/30 min.)Process pressuremax. 12 bar at 20°Cmax.174 psi at 68°FMeasuring principleConductiveApplicationPharmaceuticals, pure and ultrapure... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Analog conductivity sensor Condumax CLS15 Measurement rangek=0,01: 0-20 µS/cmk=0,1: 0-200 µS/cmProcess temperaturemax. 130°C (150°C / 30 min.)(max. 266°F (302°F/30 min.)Process pressuremax. 12 bar at 20°C(174 psi at 68°F)Measuring principleConductiveApplicationWater, power plant,... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Analog conductivity sensor Condumax CLS13 Measurement rangek=0,01: 0-20,0 µS/cmk=0,1: 0-200,0 µS/cmProcess temperaturemax. 250 °C (482 °F)Process pressuremax. 40 bar (580 psi)Measuring principleConductiveApplicationProcess, power plantCharacteristic2-electrode conductivity cell for high... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Analog conductivity sensor Condumax CLS12 Measurement rangek=0.01: 0 to 20 µS/cmk= 0.1: 0 to 200 µS/cmProcess temperature-30 to 160 °C (-22 to 320 °F)Process pressureMax. 40 bar up to 100 °C (max. 580 psi up to 212 °F) without CLA 751 flow chamberMax. 12 bar up to 150 °C (max. 174 psi up to 302... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Conductivity transmitter Liquisys CLM253 InputOne-channel transmitterOutput / communication0/4-20mA, Hart, Profibus.Ingress protectionIP65Measuring principleConductiveApplicationWater, waste water, processCharacteristic4-wire transmitter with a two-line displayDesignConductivity transmitter in... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Conductivity transmitter Liquisys CLM223 Input1-channel transmitterOutput / communication0/4-20 mA, Hart, Profibus.Ingress protectionIP65Measuring principleConductiveApplicationWater, waste water, processCharacteristic4-wire transmitter with a two-line display.DesignPanel-mounted transmitter... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital conductivity sensor Memosens CLL47E Measurement range5 μS/cm to 200 mS/cmProcess temperature0 to 100 °C (32 to 212 °F)Process pressure1 bar, not intended for continuous measurement in processMeasuring principleConductiveApplicationMeasurements where a broad conductivity measurement range... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Conductivity compact device Smartec CLD132 Measurement range100 µS/cm - 2000 mS/cmProcess temperaturemax. 140°C (max. 30 min.)284°F (max. 30 min.)Process pressuremax. 12 bar (90°C)(174 psi(194°F))Measuring principleInductiveApplication- Alkali/acid concentration control - phase separation in pipe... Add to Wishlist