Wishlist Endress+Hauser Endress+Hauser Radar measurement Time-of-Flight Micropilot FMR57 Accuracy+/- 3 mm (0.12 in)Process temperature-40...+400 °C(-40...+752 °F)Process pressure / max. overpressure limitVacuum...16 bar(Vacuum...232 psi)Max. measurement distance70 m (230 ft)Main wetted parts316L, PEEK, PTFE, PolyamidMeasuring principleLevel... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Radar measurement Time-of-Flight Micropilot FMR52 Accuracy+/- 2 mm (0.08 in)Process temperature-196...+200 °C(-321...+392 °F)Process pressure / max. overpressure limitVacuum...25 bar(Vacuum...363 psi)Max. measurement distanceStandard: 40 m (131 ft)With advanced dynamics: 60 m (197 ft)Main wetted... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Radar measurement Time-of-Flight Micropilot FMR20 Accuracy+/- 2 mm (0,08")Process temperature-40…+80°C (-40…+176°F)Process pressure / max. overpressure limit-1…3 bar (-14,5…43 psi)Max. measurement distanceDN40: 15 m (49.2 ft),DN80: 20 m (65.6 ft)Main wetted partsPVDF, PBTMeasuring principleLevel... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Radar measurement Time-of-Flight Micropilot FMR10 Accuracy+/- 5 mm (0,2")Process temperature-40…+60°C(-40…+140°F)Process pressure / max. overpressure limit-1…3 bar (-14,50…43 psi)Max. measurement distanceStandard: 8 m (26.2 ft)With flooding protection tube: 12 m (39.4 ft)Main wetted partsPVDF,... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Guided radar measurement Time-of-Flight Levelflex FMP57 AccuracyRod probe: +/- 2 mm (0.08 in)Rope probe <= 15 m (49ft):+/- 2 mm (0.08 in)Rope probe > 15 m (49ft):+/- 10 mm (0,39 in)Process temperature-40...+150 °C(-40...+302 °F)Process pressure / max. overpressure limitVacuum...16 bar(Vacuum...232... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Guided radar measurement Time-of-Flight Levelflex FMP56 AccuracyRope probe: +/- 2 mm (0.08 in)Process temperature–40...+120 °C(–40...+248 °F)Process pressure / max. overpressure limitVacuum...16 bar(Vacuum...232 psi)Max. measurement distanceRope: 12 m (40 ft)Min DK >1.4Main wetted partsRope probe:304, 316,... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Guided radar measurement Time-of-Flight Levelflex FMP55 AccuracyRod probe :+/- 2 mm (0.08 in)Rope probe:+/- 2 mm (0.08 in)Coaxial probe:+/- 2 mm (0.08 in)Process temperature-40...+200 °C(-40...+392 °F)Process pressure / max. overpressure limitVacuum...40 bar(Vacuum...580 psi)Max. measurement distanceRod: 4 m... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Guided radar measurement Time-of-Flight Levelflex FMP54 AccuracyRod probe: +/- 2 mm (0.08 in)Rope probe <= 15 m (49 ft):+/- 2 mm (0.08 in)Rope probe > 15 m (49 ft):+/- 10 mm (0.39 in)Coaxial probe: +/- 2 mm (0.08 in)Process temperatureXT: -196...+280 °C(-321...+536 °F)HT: -196...+450 °C(-321...+842... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Guided radar measurement Time-of-Flight Levelflex FMP53 AccuracyRod probe:+/- 2 mm (0.08 in)Process temperature-20...+150 °C(-4...+302 °F)Process pressure / max. overpressure limitVacuum...16 bar(Vacuum...232 psi)Max. measurement distanceRod: 6 m (20 ft)Min DK>1.6Main wetted partsRod probe:304, 304L, 316L,... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Guided radar measurement Time-of-Flight Levelflex FMP52 AccuracyRod probe :+/- 2 mm (0.08 in)Rope probe <= 15 m (49 ft):+/- 2 mm (0.08 in)Rope probe > 15 m (49 ft):+/- 10 mm (0.39 in)Process temperature-50...+200 °C(-58...+392 °F)Process pressure / max. overpressure limitVacuum...40 bar(Vacuum...580... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Guided radar measurement Time-of-Flight Levelflex FMP51 AccuracyRod probe :+/- 2 mm (0.08 in)Rope probe <= 15 m (49 ft): +/- 2 mm (0.08 in)Rope probe > 15 m (49 ft): +/- 10 mm (0.39 in)Coaxial probe: +/- 2 mm (0.08 in)Process temperature-50...+200 °C(-58...+392 °F)Process pressure / max. overpressure... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Guided radar measurement Time-of-Flight Levelflex FMP50 AccuracyRod probe: +/- 2 mm (0.08 in)Rope probe: +/- 2 mm (0.08 in)Process temperature-20...+80 °C(-4...+176 °F)Process pressure / max. overpressure limitVacuum...6 bar,(Vacuum...87 psi)Max. measurement distanceRod: 4 m (13 ft) Min DK>1.6Rope: 12 m... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Radiometric level and density measurement Gammapilot FMG50 Process temperatureAnyProcess pressure / max. overpressure limitAnyMax. measurement distanceUnlimited measuring range,CascadeAccuracy+/-1%Main wetted partsNon-contactMeasuring principleRadiometricCharacteristic / ApplicationCompact transmitter for... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Ultrasonic measurement Time-of-Flight Prosonic FDU95 Process temperature-40 °C...80 °Cor 150 °C,(-40 °F...176 °For 302 °F)Process pressure / max. overpressure limit0.7 bar...1.5 bar abs(10 psi...22 psi)Max. measurement distance45 m (148 ft)Accuracy+/- 2 mm + 0.17% of measured distanceMain wetted partsUP... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Ultrasonic measurement Time-of-Flight Prosonic FDU93 Process temperature-40 °C ... 95 °C(-40 °F ... 203 °F)Process pressure / max. overpressure limit0.7 bar ... 3 bar abs(10 psi ... 43 psi)Max. measurement distanceLiquids: 25 m (85 ft),Solids: 15 m (50 ft)Accuracy+/- 2 mm + 0.17% of measured distanceMain... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Ultrasonic measurement Time-of-Flight Prosonic FDU92 Process temperature-40 °C ... 95 °C(-40 °F ... 203 °F)Process pressure / max. overpressure limit0.7 bar ... 4 bar abs(10 psi ... 58 psi)Max. measurement distanceLiquids: 20 m (65 ft),Solids: 10 m (33 ft)Accuracy+/- 2mm + 0.17% of measured distanceMain... Add to Wishlist