Danfoss
137G4684 FC-202N400T7E5MH2TLC3XQLX1XXANBXCXXXXD0
REQUEST A QUOTE
FC-202N400T7E5MH2TLC3XQLX1XXANBXCXXXXD0
Frequency converter
FC-202N400T7E5MH2TLC3XQLX1XXANBXCXXXXD0
VLT® AQUA Drive FC-202
(N400) 400 KW / 550 HP, Three phase
525 - 690 VAC *, IP54/Type 12+main shield
RFI Filter
Safe Stop
Graphical LCP + USB
Coated PCB, Mains Disconnect + Fuse
Condition Based Monitoring CBM
EtherNet/IP MCA 121, No B Option
No C1 option, MCB-107 24V DC backup
Frame: D7H
Other options according to Model code
Model code :
FC-202N400T7E5MH2TLC3XQLX1XXANBXCXXXXD0
Danfoss VLT® AQUA Drive is dedicated to water and wastewater applications. With a wide range of powerful sta.
Gross weight | 200.3 kg |
Net weight | 200 kg |
Volume | 0 l |
EAN | 5715253307510 |
VLT® AQUA DRIVE FC 200 SERIES
Product View (Switch) | GLBL | Global (Standard) |
Product Group | FC- | VLT® AQUA Drive FC- |
Series | 202 | 202 |
Power Rating | N400 | (N400) 400 KW / 550 HP |
Phase | T | Three phase |
Mains Voltage | 7 | 525 - 690 VAC * |
Possible rating issue | WARN01 | Possible Rating Issue: |
Enclosure | E5M | IP54/Type 12+main shield |
RFI Filter | H2 | RFI Filter |
Brake - Safe Stop | T | Safe Stop |
LCP | L | Graphical LCP + USB |
Coating PCB | C | Coated PCB |
Mains Option | 3 | Mains Disconnect + Fuse |
Adaptation A | X | Standard Cable Entries |
Adaptation B | Q | Heat-sink access |
Software Release | LX1X | Condition Based Monitoring CBM |
Software Language Pack | X | Standard Language Pack |
A Option | AN | EtherNet/IP MCA 121 |
B Option | BX | No B Option |
C0 Option MCO | CX | No C0 option |
C1 Option | X | No C1 option |
C Option Software | XX | No software option |
D Option | D0 | MCB-107 24V DC backup |
Frame Size | D7H | D7H |
Typecode Part 1 | FC-202N400T7E5MH2TLC | |
Typecode Part 2 | 3XQLX1XXANBXCXXXXD0 | |
Product Catalog | NO_VIEW | NO VIEW |
Power 150% (HO) [KW] | 315 | |
Power 110% (NO) [KW] | 400 | |
Height [mm] | 1978,0 | |
Width w/ no C options [mm] | 420,0 | |
Depth [mm] | 386,0 | |
Depth with Option A/B [mm] | 386,0 | |
kVA | 478 | |
Power Loss NO [W] | 5028 | |
Power Loss NO [W] | 5155 | |
Power Loss HO [W] | 4146 | |
Power Loss HO [W] | 4258 | |
Continuous Current (NO) [A] | 418 | |
Intermittent Current (NO) [A] | 460 | |
Continuous Current (NO) [A] | 400 | |
Intermittent Current (NO) [A] | 440 | |
Continuous Current (HO) [A] | 360 | |
Intermittent Current (HO) [A] | 540 | |
Continuous Current (HO) [A] | 344 | |
Intermittent Current (HO) [A] | 516 | |
Calculated Gross Weight [kg] | 200.3 | |
Calculated Net Weight [kg] | 200 | |
Material Gross Weight | 200.3 | |
Material Net Weight | 200 | |
Plant from Orderline | F605 | |
Vendor | ERR01 | Cannot Determine Vendor |
Recommended Factory | ERR01 | Cannot Determine Vendor |
Modelcode01 | FC-202N400T7E5MH2TLC | |
Modelcode02 | 3XQLX1XXANBXCXXXXD0 |