Danfoss
137G1171 FC-202N200T4E5MH4XGRWXXSXXXXAXBKCXXXXDX
REQUEST A QUOTE
Frequency converter
FC-202N200T4E5MH4XGRWXXSXXXXAXBKCXXXXDX
VLT® AQUA Drive FC-202
(N200) 200 KW / 300 HP, Three phase
380 - 480 VAC, IP54/Type 12+main shield
RFI class A1 (C2)
No brake chopper
Graphical Loc. Cont. Panel
Coated PCB 3C3 + Ruggedised, Cable Conn. Cabinet + Fuse
Latest release std. SW.
No A Option, MCB-101 General purp. I/O
No C1 option, No D option
Frame: D7H
Other options according to Model code
Model code :
FC-202N200T4E5MH4XGRWXXSXXXXAXBKCXXXXDX
Danfoss VLT® AQUA Drive is dedicated to water and wastewater applications. With a wide range of powerful sta.
Gross weight | 200.3 kg |
Net weight | 200 kg |
Volume | 0 l |
EAN | 5715253270937 |
VLT® AQUA DRIVE FC 200 SERIES
Product View (Switch) | GLBL | Global (Standard) |
Product Group | FC- | VLT® AQUA Drive FC- |
Series | 202 | 202 |
Power Rating | N200 | (N200) 200 KW / 300 HP |
Phase | T | Three phase |
Mains Voltage | 4 | 380 - 480 VAC |
Enclosure | E5M | IP54/Type 12+main shield |
RFI Filter | H4 | RFI class A1 (C2) |
Brake - Safe Stop | X | No brake chopper |
LCP | G | Graphical Loc. Cont. Panel |
Coating PCB | R | Coated PCB 3C3 + Ruggedised |
Mains Option | W | Cable Conn. Cabinet + Fuse |
Adaptation A | X | Standard Cable Entries |
Adaptation B | X | No adaptation |
Software Release | SXXX | Latest release std. SW. |
Software Language Pack | X | Standard Language Pack |
A Option | AX | No A Option |
B Option | BK | MCB-101 General purp. I/O |
C0 Option MCO | CX | No C0 option |
C1 Option | X | No C1 option |
C Option Software | XX | No software option |
D Option | DX | No D option |
Frame Size | D7H | D7H |
Typecode Part 1 | FC-202N200T4E5MH4XGR | |
Typecode Part 2 | WXXSXXXXAXBKCXXXXDX | |
Product Catalog | GLBL | Global (Standard) |
Power 150% (HO) [KW] | 160 | |
Power 110% (NO) [KW] | 200 | |
Height [mm] | 1978,0 | |
Width w/ no C options [mm] | 420,0 | |
Depth [mm] | 386,0 | |
Depth with Option A/B [mm] | 386,0 | |
kVA | 274 | |
Power Loss NO [W] | 4116 | |
Power Loss NO [W] | 3569 | |
Power Loss HO [W] | 3093 | |
Power Loss HO [W] | 2872 | |
Continuous Current (NO) [A] | 395 | |
Intermittent Current (NO) [A] | 435 | |
Continuous Current (NO) [A] | 361 | |
Intermittent Current (NO) [A] | 397 | |
Continuous Current (HO) [A] | 315 | |
Intermittent Current (HO) [A] | 472 | |
Continuous Current (HO) [A] | 302 | |
Intermittent Current (HO) [A] | 453 | |
Calculated Gross Weight [kg] | 200.3 | |
Calculated Net Weight [kg] | 200 | |
Plant from Orderline | F605 | |
Vendor | ERR01 | Cannot Determine Vendor |
Recommended Factory | ERR01 | Cannot Determine Vendor |
Modelcode01 | FC-202N200T4E5MH4XGR | |
Modelcode02 | WXXSXXXXAXBKCXXXXDX |