Danfoss
136L4360 FC-202P55KT7E55H5TGCXXXSXXXXAXBXCXXXXDX
REQUEST A QUOTE
Frequency converter
FC-202P55KT7E55H5TGCXXXSXXXXAXBXCXXXXDX
VLT® AQUA Drive FC-202
(P55K) 55 KW / 75 HP, Three phase
525 - 690 VAC *, IP55 / Type 12
Marine,ruggedis RFI A2(C3)
Safe Stop
Graphical Loc. Cont. Panel
Coated PCB, No Mains Option
Latest release std. SW.
No A Option, No B Option
No C1 option, No D option
Frame: C2
Other options according to Model code
Model code :
FC-202P55KT7E55H5TGCXXXSXXXXAXBXCXXXXDX
Danfoss VLT® AQUA Drive is dedicated to water and wastewater applications. With a wide range of powerful sta.
Gross weight | 65.3 kg |
Net weight | 65 kg |
Volume | 228.095 l |
EAN | 5710108809522 |
VLT® AQUA DRIVE FC 200 SERIES
Product View (Switch) | GLBL | Global (Standard) |
Product Group | FC- | VLT® AQUA Drive FC- |
Series | 202 | 202 |
Power Rating | P55K | (P55K) 55 KW / 75 HP |
Phase | T | Three phase |
Mains Voltage | 7 | 525 - 690 VAC * |
Possible rating issue | WARN01 | Possible Rating Issue: |
Enclosure | E55 | IP55 / Type 12 |
RFI Filter | H5 | Marine,ruggedis RFI A2(C3) |
Brake - Safe Stop | T | Safe Stop |
LCP | G | Graphical Loc. Cont. Panel |
Coating PCB | C | Coated PCB |
Mains Option | X | No Mains Option |
Adaptation A | X | Standard Cable Entries |
Adaptation B | X | No adaptation |
Software Release | SXXX | Latest release std. SW. |
Software Language Pack | X | Standard Language Pack |
A Option | AX | No A Option |
B Option | BX | No B Option |
C0 Option MCO | CX | No C0 option |
C1 Option | X | No C1 option |
C Option Software | XX | No software option |
D Option | DX | No D option |
Frame Size | C2 | C2 |
Typecode Part 1 | FC-202P55KT7E55H5TGC | |
Typecode Part 2 | XXXSXXXXAXBXCXXXXDX | |
Product Catalog | GLBL | Global (Standard) |
Power 150% (HO) [KW] | 45 | |
Power 110% (NO) [KW] | 55 | |
Height [mm] | 770,0 | |
Width w/ no C options [mm] | 370,0 | |
Depth [mm] | 335,0 | |
Depth with Option A/B [mm] | 335,0 | |
kVA | 74.1 | |
Power Loss NO [W] | 1100 | |
Power Loss NO [W] | 1100 | |
Power Loss HO [W] | 900 | |
Power Loss HO [W] | 900 | |
Continuous Current (NO) [A] | 65 | |
Intermittent Current (NO) [A] | 71.5 | |
Continuous Current (NO) [A] | 62 | |
Intermittent Current (NO) [A] | 68.2 | |
Continuous Current (HO) [A] | 54 | |
Intermittent Current (HO) [A] | 81 | |
Continuous Current (HO) [A] | 52 | |
Intermittent Current (HO) [A] | 78 | |
Calculated Gross Weight [kg] | 59.3 | |
Calculated Net Weight [kg] | 59 | |
Material Gross Weight | 65.3 | |
Material Net Weight | 65 | |
Vendor | ERR01 | Cannot Determine Vendor |
Recommended Factory | ERR01 | Cannot Determine Vendor |
Modelcode01 | FC-202P55KT7E55H5TGC | |
Modelcode02 | XXXSXXXXAXBXCXXXXDX |
Returns Policy