Danfoss
132X0216 FC-202P55KT4P55H2XGCXXXSXXXXAXBKCXXXXDX
REQUEST A QUOTE
Frequency converter
FC-202P55KT4P55H2XGCXXXSXXXXAXBKCXXXXDX
VLT® AQUA Drive FC-202
(P55K) 55 KW / 75 HP, Three phase
380 - 480 VAC, IP55 / Type12 Backplate
RFI Filter
No brake chopper
Graphical Loc. Cont. Panel
Coated PCB, No Mains Option
Latest release std. SW.
No A Option, MCB-101 General purp. I/O
No C1 option, No D option
Frame: C1
Other options according to Model code
Model code :
FC-202P55KT4P55H2XGCXXXSXXXXAXBKCXXXXDX
Danfoss VLT® AQUA Drive is dedicated to water and wastewater applications. With a wide range of powerful sta.
Gross weight | 43.5 kg |
Net weight | 43.2 kg |
Volume | 228.095 l |
EAN | 5715253149158 |
VLT® AQUA DRIVE FC 200 SERIES
Product View (Switch) | GLBL | Global (Standard) | |
Product Group | FC- | VLT® AQUA Drive FC- | |
Series | 202 | 202 | |
Power Rating | P55K | (P55K) 55 KW / 75 HP | |
Phase | T | Three phase | |
Mains Voltage | 4 | 380 - 480 VAC | |
Enclosure | P55 | IP55 / Type12 Backplate | |
RFI Filter | H2 | RFI Filter | |
Brake - Safe Stop | X | No brake chopper | |
LCP | G | Graphical Loc. Cont. Panel | |
Coating PCB | C | Coated PCB | |
Mains Option | X | No Mains Option | |
Adaptation A | X | Standard Cable Entries | |
Adaptation B | X | No adaptation | |
Software Release | SXXX | Latest release std. SW. | |
Software Language Pack | X | Standard Language Pack | |
A Option | AX | No A Option | |
B Option | BK | MCB-101 General purp. I/O | |
C0 Option MCO | CX | No C0 option | |
C1 Option | X | No C1 option | |
C Option Software | XX | No software option | |
D Option | DX | No D option | |
Frame Size | C1 | C1 | |
Typecode Part 1 | FC-202P55KT4P55H2XGC | ||
Typecode Part 2 | XXXSXXXXAXBKCXXXXDX | ||
Product Catalog | NO_VIEW | NO VIEW | |
Power 150% (HO) [KW] | 45 | ||
Power 110% (NO) [KW] | 55 | ||
Height [mm] | 680,0 | ||
Width w/ no C options [mm] | 308,0 | ||
Depth [mm] | 310,0 | ||
Depth with Option A/B [mm] | 310,0 | ||
kVA | 73.4 | ||
Power Loss NO [W] | 1083 | ||
Power Loss NO [W] | 1083 | ||
Power Loss HO [W] | 891 | ||
Power Loss HO [W] | 891 | ||
Continuous Current (NO) [A] | 106 | ||
Intermittent Current (NO) [A] | 117 | ||
Continuous Current (NO) [A] | 105 | ||
Intermittent Current (NO) [A] | 116 | ||
Continuous Current (HO) [A] | 90 | ||
Intermittent Current (HO) [A] | 135 | ||
Continuous Current (HO) [A] | 80 | ||
Intermittent Current (HO) [A] | 120 | ||
Calculated Gross Weight [kg] | 44.8 | ||
Calculated Net Weight [kg] | 44.5 | ||
Material Gross Weight | 43.5 | ||
Material Net Weight | 43.2 | ||
Plant from Orderline | D902 | ||
Vendor | ERR01 | Cannot Determine Vendor | |
Recommended Factory | ERR01 | Cannot Determine Vendor | |
Allowed Plants | B901 D902 | (B901) Graasten Manufactoring (D902) Kimpo Distribution | |
Modelcode01 | FC-202P55KT4P55H2XGC | ||
Modelcode02 | XXXSXXXXAXBKCXXXXDX |